AMBIENT AIR ANO DUST SAMPLING PROTOCOL for PS234M. Page 4 of8

{: in the event that real-time measurement(s) of TVOC inside the school is/are above the cited Target Guidelines (Ippm), ATC shall immediately notify BOE representative Mr. Mohamed Hemida, the UFT and the PA consultant. BOE shall notify the school principal, the school custodian and the plant manager. The said parties will assess the situation and implement the appropriate response action(s) immediately.

In the event that real-time measurement(s) of 0.5 ppm of TVOC are obtained inside the school ATC shall immediately notify BOE representative Mr. Mohamed Hemida, the UFT and the PA consultant. BOE shall notify the school principal, the school custodian and the plant manager. The said parties will assess the situation and implement the appropriate response action(s) immediately.

ADDITIONAL TESTING

In addition to the above, once per week, preferably on Saturday, sampling settled dust for fiberglass, lead, and silica; wipe sampling for dioxin and PCB and air sampling, for heavy metals, and TVOCs shall be performed as follows:

SETTLED FIBERGLASS

• First floor hallway - one sample.

• Cafeteria - one sample.

• Gymnasium - one sample.

• Auditorium - one sample.

• Two Classrooms facing south - 2 samples (one sample in each randomly selected classroom immediately after the last class)

• Classroom facing east - one sample in a randomly selected classroom immediately after the last class. »

Dust bulk samples will be collected at the aforementioned locations and analyzed via Polarized Light Microscopy (PLM). In the event that in any of the above locations there is not sufficient amount of dust for bulk sampling and/or analysis will be noted as Not Sufficient Amount of Material for Testing (NSAMT)

In the event that any of PLM analysis detect more than 1% by weight of fiberglass, BOE will immediately notify the UFT, the school principal, the school custodian and the PA consultant. The said parties will assess the situation and implement the appropriate response action(s).

LEAD SURFACE DUST

• First floor hallway - one sample.

L • Cafeteria - one sample.

CITY_21MC100_003267255

NYC-WTC_000324206

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000324206Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →