NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 414 pages

Ground Zero environmental health schools report

Machine-extracted title · confidence 45%

Document discussing lessons learned in children's environmental health related to Ground Zero sites.

NYC-WTC_000276036–000276449
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

AMBIENT AIR AND DUST SAMPLING PROTOCOL for PS234M, Page 4 of 7

school custodian and the PA consultant. The said parties will assess the situation and implement the appropriate response action{s).

In the event that real-time measurement(s) of 0.5 ppm of TVOC are obtained inside the school BOE will notify the UFT, the school principal, the school custodian and the PA consultant. The said parties will assess the situation and implement the appropriate response actionfs)

ADDITIONAL TESTING

In addition to the above, once per week, preferably on Tuesday, sampling settled dust for fiberglass, lead, and silica; wipe sampling for dioxin and PCB and air sampling, for heavy metals, and TVOCs shall be performed as follows:

SETTLED FIBERGLASS

• First floor hallway - one sample.

• Cafeteria - one sample.

• Gymnasium - one sample.

• Auditorium - one sample.

• Two Classrooms facing south - 2 samples (one sample in each randomly selected classroom immediately after the last class)

• Classroom facing east - one sample in a randomly selected classroom immediately after the last class.

Dust bulk samples will be collected at the aforementioned locations and analyzed via Polarized Light Microscopy (PLM). In the event that in any of the above locations there is not sufficient amount of dust for bulk sampling and/or analysis will be noted as Not Sufficient Amount of Material for Testing (NSAMT)

In the event that any of PLM analysis detect more than 1% by weight of fiberglass, BOE will immediately notify the UFT, the school principal, the school custodian and the PA consultant. The said parties will assess the situation and implement the appropriate response action(s).

LEAD SURFACE DUST

• First floor hallway - one sample.

• Cafeteria - one sample.

• Gymnasium - one sample.

• Auditorium - one sample.

CITY_21MC100_012173120

NYC-WTC_000276275

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000276275Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000106411 · Box DEP Box 37

Union memorandum regarding environmental monitoring and cleanup protocols following the closure of Stuyvesant High School after the September 11 attacks.

Similar indexed content

NYC-WTC_000149798 · Box DEP Box 10

Generic form or header page from the Department of Environmental Protection regarding general World Trade Center notices and requests.

Similar indexed content

Compare copies and versions →