AMBIENT AIR AND DUST SAMPLING PROTOCOL for PS234M. Page 5 of 8
• Gymnasium - one sample.
• Auditorium - one sample.
• Two Classrooms facing south - 2 samples (one sample in each randomly selected classroom immediately after the last class)
• Classroom facing east - one sample in a randomly selected classroom immediately after the last class.
• First floor (Throughout) - Additional minimum of five (5) samples within classrooms where present. One sample shall be collected within every Pre-K and Kindergarten classroom where present.
• Second floor Hallways south end - one sample immediately after the last class.
Second floor Classrooms - Additional minimum of five (5) samples within classrooms where present. One sample shall be collected within every Pre-K and Kindergarten classroom where present.
• Third floor Classrooms - Additional minimum of five (5) samples within classrooms where present. One sample shall be collected within every Pre-K and Kindergarten classroom where present.
• Outside Playground - three samples on playground surface after last class.
• Exterior Building Entrances - one sample on ground at exterior main entrances.
All dust wipe samples taken shall be analyzed in accordance with EPA7082 method via Flame Atomic Absorption (FAA).
Dust wipe results shall be considered satisfactory when the levels obtained are below the EPA new levels for clearing a work area for re-occupancy after an EPA defined lead abatement is performed, as specified in 40 CFR §745.227(e)(8)(viii).
Floors: 40 micrograms of lead per square foot Window Sills: 250 micrograms of lead per square foot Exterior Concrete or Rough Surfaces: 800 micrograms of lead per square foot
Dust wipe results shall be considered unsatisfactory when the levels obtained are greater than the EPA new levels for clearing a work area for re-occupancy after an EPA defined lead abatement is performed, as specified in 40 CFR §745.227(e)(8)(viii).
Floors; 40 micrograms of lead per square foot Window Sills: 250 micrograms of lead per square foot Exterior Concrete or Rough Surfaces: 800 micrograms of lead per square foot
CITY_21MC100_003267256
NYC-WTC_000324207
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000324159
Ambient air/dust protocol for PS 234 Manhattan; asbestos IAQ.
16 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000324185
Ambient air sampling plan for PS 150 Manhattan; asbestos IAQ.
16 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000234651
Draft protocol document outlining daily asbestos testing procedures for ambient air at P.S./I.S. 89 Manhattan following the WTC tragedy.
16 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000453730
Draft ambient air and dust sampling protocol for IAQ/asbestos monitoring at PS 89 Manhattan.
16 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000324143
Ambient air and dust sampling protocol for PS 150 in Manhattan.
16 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000385777
Protocol for ambient air and dust sampling around PS 234 post-WTC cleanup.
16 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000385787
Ambient air sampling protocol for PS 234 with daily inside/outside tests.
16 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000385841
Ambient air and dust sampling protocol for PS 150 Manhattan after WTC events.
16 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000236847
Draft protocol document outlining daily ambient air and dust sampling procedures for PS/IS 89 following the World Trade Center tragedy.
16 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000236904
Draft protocol for daily ambient air and dust sampling at P.S./I.S. 89 to monitor potential asbestos contamination.
16 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000236871
Draft protocol document outlining daily ambient air and dust sampling procedures for PS/IS 89 following the World Trade Center tragedy.
16 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000385819
Lab protocol outlining ambient air and dust sampling for asbestos at IS 89 Manhattan.
16 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000385777
Protocol for ambient air and dust sampling around PS 234 post-WTC cleanup.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000385787
Ambient air sampling protocol for PS 234 with daily inside/outside tests.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000324159
Ambient air/dust protocol for PS 234 Manhattan; asbestos IAQ.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000385808
Protocol detailing daily ambient air sampling inside the IS 89 building.
Similarity score 0.994 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000385797
Ambient air/dust sampling protocol for IS 89 after WTC cleanup.
Similarity score 0.994 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000385819
Lab protocol outlining ambient air and dust sampling for asbestos at IS 89 Manhattan.
Similarity score 0.994 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000385777
Protocol for ambient air and dust sampling around PS 234 post-WTC cleanup.
Similar indexed content
NYC-WTC_000385787
Ambient air sampling protocol for PS 234 with daily inside/outside tests.
Similar indexed content
NYC-WTC_000324159
Ambient air/dust protocol for PS 234 Manhattan; asbestos IAQ.
Similar indexed content
NYC-WTC_000385841
Ambient air and dust sampling protocol for PS 150 Manhattan after WTC events.
Similar indexed content
NYC-WTC_000324185
Ambient air sampling plan for PS 150 Manhattan; asbestos IAQ.
Similar indexed content