NYC 9/11 Public Portal Document
ATC Environmental, Inc. 104 East 25th Street New York, New York 10010
N.Y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date: 10/19/01 ASB3STOS FIBER ANALYSIS BY TRANSMISSION lECTRON MICROSCOPY (TEM) With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS) Method; AHERA Final Rule, EPA Federal Register [40 CFR, Part 763), Vol. 51, No. 210, October 3C, 1987
SainuleldentlficaLion Ansilvsis ParaiTiecers
Project/Sice: P.S. 130M, 143 Baxter St.. NY, NY TEM Sannle No.: 5726 61563 Thrcuchout the School Building Date Received: 10/18/^ Grid Openings Analyzed:__4
Project Sample No.: 08 Average Grid Opening: 105.00 urn
Air Volume: iters Total Area Analysed :0^0£50Tnn^
Filter Th’p e: MCE 25 mm diam. , Pore Size: C.45 urn Analytical Sensitivity:2Zj-2 s/TTir^ Effective Area? 385 mmS 0.QQ45 s/cc
FIBROUS PARTICULATES AN.ALYZED NuTTiber Observed CONCENTRATION Total Single Matrix Total. Struct. Filter Air Fibers Bundles Clusters Struct. Struct > = 5um Struct/mmS Struct/cc nam ni3
Chrysotile Asbestos 0 0 C 0 C 0 C .0 0.0000 0
Amphibole Asbestos 0 0 0 0 0 0 0.0 0.oooo 0
AinbiguouE 0 0 0 0 0 0 C.O 0.0000 D
Total asbestos (includes ambiguous'’structures) 0 0 C.O 0.0000 0 Non-Asbestos 0 0 0 c 0 0 C.O 0.0000 N/A No Identification 0 0 0 0 0 0 0.0 0.0000 N/A
Totals (All Structures) 0 0 0.0 0.0000 N/A The estimated uncertainty of this analysis is 1 standard deviation.
■ Non-asbestos fiber i.d. (EDS/SAED): None decected Amphibole Asbestos Type: None detected
The Analysis was carried out in accordance wish the approved TEM method. This laboratory is in compliance with the quality specified for the method.
Analyzed by: Report Reviewed by:
Michael A. Gorycki, Ph.D. Michael A. Gorycki, Fh.D. Director of Electren Microscopy
CITY_21MC100_011274403
NYC-WTC_000324064
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000329848
Asbestos fiber analysis by TEM for PS 130M school.
8 shared non-person entities · 1 shared topics · similarity 0.989
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000329868
TEM asbestos analysis with SAED/EDS; AHERA methods; PS 13OM site across building; 10/19/01.
8 shared non-person entities · 1 shared topics · similarity 0.989
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000324065
TEM analysis parameters and results for PS 130M project; building-wide sampling.
7 shared non-person entities · 1 shared topics · similarity 0.989
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000324075
TEM/SAED/EDS asbestos analysis; AHERA method; PS 130M building.
7 shared non-person entities · 1 shared topics · similarity 0.989
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000329852
TEM asbestos analysis results for PS 130M site.
7 shared non-person entities · 1 shared topics · similarity 0.989
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000324080
Asbestos fiber TEM analysis identifying fibers with SAED/EDS, PS 130M, throughout the school building, Oct 2001.
6 shared non-person entities · 1 shared topics · similarity 0.989
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000329849
TEM asbestos analysis at PS 130M, school building sampling.
8 shared non-person entities · 1 shared topics · similarity 0.988
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000262765
TEM asbestos analysis of a PS 234M sample for AHERA scope, with SAED/EDS identification.
7 shared non-person entities · 1 shared topics · similarity 0.988
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000202620
Laboratory TEM analysis of air samples collected at PS 13QM to detect asbestos fibers using EPA methods.
7 shared non-person entities · 1 shared topics · similarity 0.988
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000329871
TEM asbestos analysis; SAED/EDS; PS 110M project/site; 10/18/01.
7 shared non-person entities · 1 shared topics · similarity 0.988
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000411527
TEM analysis with SAED/EDS for PS 234M, Oct 2, 2001.
6 shared non-person entities · 1 shared topics · similarity 0.988
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000329870
TEM asbestos analysis; SAED/EDS; P.S. 130M; 10/18/01.
8 shared non-person entities · 1 shared topics · similarity 0.988
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000329848
Asbestos fiber analysis by TEM for PS 130M school.
Similarity score 0.995 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000329868
TEM asbestos analysis with SAED/EDS; AHERA methods; PS 13OM site across building; 10/19/01.
Similarity score 0.995 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000324065
TEM analysis parameters and results for PS 130M project; building-wide sampling.
Similarity score 0.994 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000324075
TEM/SAED/EDS asbestos analysis; AHERA method; PS 130M building.
Similarity score 0.994 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000329852
TEM asbestos analysis results for PS 130M site.
Similarity score 0.994 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000324080
Asbestos fiber TEM analysis identifying fibers with SAED/EDS, PS 130M, throughout the school building, Oct 2001.
Similarity score 0.994 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000329848
Asbestos fiber analysis by TEM for PS 130M school.
Similar indexed content
NYC-WTC_000329868
TEM asbestos analysis with SAED/EDS; AHERA methods; PS 13OM site across building; 10/19/01.
Similar indexed content
NYC-WTC_000324065
TEM analysis parameters and results for PS 130M project; building-wide sampling.
Similar indexed content
NYC-WTC_000324075
TEM/SAED/EDS asbestos analysis; AHERA method; PS 130M building.
Similar indexed content
NYC-WTC_000329852
TEM asbestos analysis results for PS 130M site.
Similar indexed content