NYC-WTC_000202620
Laboratory TEM analysis of air samples collected at PS 13QM to detect asbestos fibers using EPA methods.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗TEM asbestos analysis at PS 130M, school building sampling.
NYC-WTC_000329849OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
ATC Environmental, Inc. 104 East 25th Street New York, New York 10010
N.y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date: 10/19/01
ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fiber Identification by Selected-Area Electron Diffraction (SAEDI and Energy-Dispersive X-RAY Spectroscopy (EDS] Method: AHERA Final Rule. EPA Federal Register (40 CPR, Part 7631, Vol. 52, No. 210, October 30, 1987
Sample Ident ificat- i or. Analysis Parameters
Project/Site; PS. 130M, 143 Baxter St., NY, NY TEM Sample No.: 5726 61661 Throuahcut the School Building Date Received: ]0/18/01 Grid Openings Arxalvaed: J
Project. Sample No. : 06 Average Grid Opening: 106.00 urn
Air Vol time : 1908 liters Total Area Analyzed : D^04^^nTn^
Filter Type: MCE 2o mrr. diam., Pore Size: 0.45 ucr Analytical Sensitivity: _22,2 s/mrn2 Effective Area; 385 mm2 0.0045 s/cc
FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single Matrix Total. Struct. Filter Air Fibers Bundles Clusters Struct. Struct ? = 5um Struct/mm2 Struct/cc nqm/mS
Chrysotile Asbestos 0 0 0 c 0 0 0,0 0.0000 0
Amphibole Asbestos 0 0 0 G 0 0 0 . 0 0.0000 0
Ambiguous 0 C 0 c 0 0 0. 0 0.0000 0
Total asbestos (includes ambiguous structures’ 0 0.c 0.0000 0 Non-Asbestcs 0 0 0 0 0 0 0. 0 0.0000 N/A No Identification 0 0 0 0 0 0. 0 0.0000 N/A
Totals (All Structures) 0 0 D.0 0.0000 N/A The estimated uncertainty of this analysis is 1 standard deviation.
Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type: None detected
The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compltance with the quality specified for the method.
Analyzed, by. Report Reviewed by:
Michael A. Gorycki, Ph.D. Michael A. Gorycki, Ph.D. Director of Electron Microscopy
CITY_21MC100_003273856
NYC-WTC_000329849
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000202620
Laboratory TEM analysis of air samples collected at PS 13QM to detect asbestos fibers using EPA methods.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000324339
TEM analysis with SAED/EDS for PS 234M, Oct 2001.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000329863
TEM asbestos fiber analysis performed across the school building on 10/16/01 for P.S. 130M.
8 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000329872
TEM asbestos analysis; SAED/EDS; 10/18/01.
6 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000329848
Asbestos fiber analysis by TEM for PS 130M school.
8 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000329853
TEM asbestos analysis results, PS 130M building-wide.
8 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000329867
TEM asbestos analysis; SAED/EDS identification; project/site PS 130M, throughout building; 10/19/01.
5 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000202619
Laboratory TEM analysis of air samples collected at PS 13QM to detect asbestos fibers using EPA methods.
7 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000329868
TEM asbestos analysis with SAED/EDS; AHERA methods; PS 13OM site across building; 10/19/01.
8 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000411527
TEM analysis with SAED/EDS for PS 234M, Oct 2, 2001.
6 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000329855
TEM asbestos analysis data for PS 130M school building.
8 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000411526
TEM analysis with SAED/EDS for PS 234M, Oct 2, 2001.
7 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000202620
Laboratory TEM analysis of air samples collected at PS 13QM to detect asbestos fibers using EPA methods.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000329863
TEM asbestos fiber analysis performed across the school building on 10/16/01 for P.S. 130M.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000329872
TEM asbestos analysis; SAED/EDS; 10/18/01.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000329848
Asbestos fiber analysis by TEM for PS 130M school.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000329853
TEM asbestos analysis results, PS 130M building-wide.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000329867
TEM asbestos analysis; SAED/EDS identification; project/site PS 130M, throughout building; 10/19/01.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000202620
Laboratory TEM analysis of air samples collected at PS 13QM to detect asbestos fibers using EPA methods.
Similar indexed content
NYC-WTC_000324339
TEM analysis with SAED/EDS for PS 234M, Oct 2001.
Similar indexed content
NYC-WTC_000329863
TEM asbestos fiber analysis performed across the school building on 10/16/01 for P.S. 130M.
Similar indexed content
NYC-WTC_000329872
TEM asbestos analysis; SAED/EDS; 10/18/01.
Similar indexed content
NYC-WTC_000329848
Asbestos fiber analysis by TEM for PS 130M school.
Similar indexed content