ATC Environmental, Inc. 104 East 25th Street New York, New York 10010

N.Y.C. Board of Education Approved N.Y. State ELAP 4^10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date: 10/19/01

ASB3ST0S FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS) Method: AHER.A Final Rule, E?A Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 30, 1987

Sample idenciSLcacior .Analysis parameters

Project/Site: 130M, 143 Baxter St., NY. NY TEM Sample No.: 5726 61664 Throuchout the School Building Dace Received:io/182^ Grid Openings Analyzed:__ 4

Project Sample No.;_09 Average Grid Opening: 106.00 um

Air Voijme: 1908 liters Total Ares Analyzed; C.0450 mm2

Filter Type; MCE 25 mm diam., Pore Size: 0.45 um Analytical Sensitivity:22 V s/m!ri2 Effective Area: 385 mm2 0.0045 s/cc

FIBROUS PARTICULATES ANALYZED Nurrloer Observed CONCENTRATION Total Single Matrix Total. Struct. Filter Air Fibers Bundles Clusters Struct. Struct >=5um Struct .'mm2 Struct/cc nq-m/m?

Chrysotile .Asbestos 0 0 0 C c c 0.0 0.0000 0

Amphibole Asbestos 0 0 0 c c c 0.0 0.0000 0

Ambiguous 0 0 0 C c c 0.0 0.0000 0

Total asbestos {includes ambiguous .structures) 0 c C.0 0.0000 0 Non-Asbestos 0 0 0 0 0 c C.0 0.0000 N/A No Ident if i ca t ion 0 0 0 0 0 0 e. 0 0.0000 N/A

Totals ;a11 Structures) 0 0 C.0 0.0000 N/A The estimated uncertainty of this analysis is 1 standard deviation.

Non-asbestos fiber i.d. (EDS/SAED): None detected .Amphibole Asbestos Type: None detected

The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.

Analyzed by: Report Reviewed by:

Michael A. Sorycki, Ph.D. Michael A. Gorycki, Ph.D. Director of Electron Microscopy

CITY_21MC1OO_O11274404

NYC-WTC_000324065

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000324065Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →