NYC 9/11 Public Portal Document
Ambient Air Sampling Locations
NYC / ER (Sep 27-28) - Volatile Organic C ompounds
o 9 (Summa) samples collected over a period of approximately 24 hours at previously
established air sampling stations (A, B, Cl, E, F, P, S, and R) near or just beyond the
perimeter of the debris piles.
o VOCs were either not detected or below the EPA Removal Action guidance levels
(based on a 30-year exposure).
o Evidence that ambient VOC concentrations at the perimeter are significantly reduced
as compared to results of grab samples collected on the debr is pile in the plume at
ground level.
NYC / ER (Oct 23) - Particulate Monitoring (PM2 5)
O Pace University (Site 1) - 24-hr average concentration for this period was 16.74 ug/m ’.
o Manhattan Boro Community College (Site 2) - 24-hour average concentration for this
period was 19.33 ug/m^.
o Coast Guard Building - Battery Park (Site 3) - 24-hour average concentrations for this
period was 19.93 ug/m^.
o All readings below the National Ambient Air Quality Standard for PYL s (65 ug/mQ.
NYC / ER (Oct 24) - Particulate Monitoring (PM, ,)
o Pace University (Site 1) - 24-hr average concentration for this period was 20.92 ug/ni\
o Manhattan Boro Community College (Site 2) - 24-hour average concentration for this
period was 24.44 ug/m\
o Coast Guard Building - Battery Park (Site 3) - 24-hour average concentrations for this
period was 19.75 ug/m'.
o All readings below the National Ambient Air Quality Standard for PYL s (65 ug/m^).
NYC / ER (Oct 25) - Particulate Monitoring (PM2 5)
o Pace University (Site 1) - 24-hr average concentration for this period was 20.54 ug/m/
o Manhattan Boro Community College (Site 2) - 24-hour average concentration for this
period was 12.38 ug/nr.
o Coast Guard Building - Battery Park (Site 3) - 24-hour average concentrations for this
period was 10.53 ug/nt^.
o All readings below the National Ambient Air Quality Standard for PM, , (65 ug/m’).
NYC / ER (Oct 25) - Particulate Monitoring (Dataram )
o Particulate levels noted at three locations (Stations L, N, R) were below the OSHA
TWA.
o Instruments operated approxim ately 6 hours.
o Station L values ranged from 55.1 to 260.8 ug/m3 with an average of 81.2 ug/m’.
o Station N values ranged from 40.2 to 66.7 ug/m3 with an average of 45.4 ug/m’.
o Station R values ranged from 40.8 to 68.5 ug/m3 with an average of 47.6 ug/m’.