Page image not rendered yet. The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text
OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
NYC / ER (Oct 25) - Volatile organics (TAGA)
o Benzene exceeded OSHA TWA PEL (1 ppm) at two locations on the debris pile in the
plume at ground level.
o Chlorodifluoromethane (Freon-22) was detected and confirmed in the North Tower
debris pile (530 ppbv) and at the South Tower debris pile (170 ppbv), both at ground
level.
o Chlorodifluoromethane levels were well below the NIOSH Recommended Exposure
Limit (REL) TWA of 1,000 ppm.
o Chlorodifluoromethane was not detected at Austin Tobin Plaza (Location 3A).
Direct Reading Instruments
NYC / ER (Oct 25)
o Several readings noted above the carbon m onoxide NAAQS (8 hr. average) of 9 ppm,
but below the NAAQS (1 hr. average) of 35 ppm and the OSHA PEL of 50 ppm.
CITY_21MC100_002458865
NYC-WTC_000321275
OCR can misread numbers and units. Confirm readings against the page image before using them.
NYC-WTC_000321275Source: NYC Law Department, mirrored locally
EPA air sampling results at Fresh Kills and related sites in January 2002, with several samples affected by equipment issues and metals testing results.