NYC-WTC_000318918
Draft EPA/NYC response background report for WTC air sampling, March 2003.
33 shared non-person entities · 1 shared topics · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗Oldraft report for World Trade Center background study prepared for FEMA, EPA Region 2.
NYC-WTC_000320385–000320529OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
•a
space had wipe samples collected from hard surfaces including ceilings, counters, floors, and walls. The samples collected from the ceiling, cormters, and walls in the common spaces were all below the detection limit and a UCL could not be calculated for these surfaces. All of the surfaces sampled from the residential areas had UCLs that were within a factor of three. Given that the residential data for the different surfaces were similar, as well as the data from the common areas, it is recommended to use the entire data set, which includes the residential and common spaces. This data set provides a 95% UCL of 52 s/cm^ as a background concentration for MMVF on hard surfaces.
6.-2;3Uead Bulk Dust - There were nine bulk dust samples collected from residential spaces aiiq analyzed for lead. There were no bulk dust samples collected from the cQnimoh’'areas. Lead was detected in all of the bulk samples ranging from 44 mg/kg to 242 mg/kg with a mean concentration of 126 mg/kg. The 95% UCL for this data set was calculated a'S'TSb mg/kg. This UCL is recommended to be used as a background concentration for lead in bulk dust. if/ Air - There were foity-six air samples collected, with thirty-two samples collected from residential areas and fourteen collected from common areas. Only one sample, collected from a residential area, had a concentration of lead that was detectable and the lead concentration was equal to the detection limit. However, as the detection limit for the common areas and residential area samples varied slightly, a theoretical background concentration can be calculated for the common area because the range of detection Umits^permits a standard deviation to be calculated. The results indicate that jlie frequency of detection is similar between the residential areas (3%) and the common areas (0%), as well as the mean concentration. The UCL for each space is similar, 0.027 pg/m’ for common areas and 0.032 pg/m^ for the residential area, therefore it is recommended to use the entire data set, which includes the common area and residential area, to calculate a background concentration. The 95% UCL for the entire 3ata set, which should be considered the calculated background concentration, jsfr.03 pg/m\
Microvacuum - There were 144 microvacuum samples collected, with 114 collected in residential areas and 18 collected in common areas. The-p-xr^a^a microvacuum samples were collected from porous materials including carpets, couches, chairs, and drapes. The frequency of detection for all of the microvacuum samples collected in the residential areas (8%) was simil^^o the samples collected in the common areas (6%), as were the ranges, mean, and calculated UCLs for the data sets for each space and each surface. Given the similarity between the data sets, both between spaces and between surfaces, it is recommended to use the entire microvacuum data set for estimating the background concentration of lead in porous surfaces. This yields a 95% UCL of 1.98 pg/ft^ for the background concentration of lead in porous surfaces.
Wipe - There were 114 wipe samples collected, with 80 collected in residential areas and 34 collected in common areas. The wipe samples were collected from WORLD TRADE CENTER BACKGROUND STUDY 22
CITY_21MC100_0 04053178
NYC-WTC_000320412
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000318918
Draft EPA/NYC response background report for WTC air sampling, March 2003.
33 shared non-person entities · 1 shared topics · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000301612
Draft report prepared for FEMA on WTC indoor air; authoring agency EPA Region 2.
30 shared non-person entities · 1 shared topics · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000242989
COPC committee reporting contributors for WTC-related contaminant list.
43 shared non-person entities · 1 shared topics · similarity 0.985
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000242900
Draft section describing selection of contaminants of potential concern.
43 shared non-person entities · 1 shared topics · similarity 0.983
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000276613
Attachment A: World Trade Center sampling and ancillaries; document header only.
38 shared non-person entities · 1 shared topics · similarity 0.983
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000319976
Contributors list for COPC committee on contaminants at World Trade Center site.
46 shared non-person entities · 1 shared topics · similarity 0.983
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000199582
Report prepared by a committee detailing contaminants of concern associated with the World Trade Center site.
38 shared non-person entities · 1 shared topics · similarity 0.982
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000242774
Laboratory assessment of contaminants related to World Trade Center dust, prepared by COPC committee participants.
39 shared non-person entities · 1 shared topics · similarity 0.982
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000145869
Interim final report from EPA Region 2 detailing a background study of environmental conditions at the World Trade Center site.
63 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000418482
WTC background study interim final report prepared for FEMA and EPA contractors.
33 shared non-person entities · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000348699
COPC committee report with contributors from EPA, NYC DEP, and state agencies.
46 shared non-person entities · 1 shared topics · similarity 0.985
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000348649
COPC committee report on World Trade Center contaminants with multi-agency authors.
44 shared non-person entities · 1 shared topics · similarity 0.985
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000318918
Draft EPA/NYC response background report for WTC air sampling, March 2003.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000301612
Draft report prepared for FEMA on WTC indoor air; authoring agency EPA Region 2.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000418482
WTC background study interim final report prepared for FEMA and EPA contractors.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000145869
Interim final report from EPA Region 2 detailing a background study of environmental conditions at the World Trade Center site.
Similarity score 0.976 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000301612
Draft report prepared for FEMA on WTC indoor air; authoring agency EPA Region 2.
Similarity score 0.969 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000318918
Draft EPA/NYC response background report for WTC air sampling, March 2003.
Similarity score 0.968 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000145869
Interim final report from EPA Region 2 detailing a background study of environmental conditions at the World Trade Center site.
Similar indexed content
NYC-WTC_000318918
Draft EPA/NYC response background report for WTC air sampling, March 2003.
Similar indexed content
WTC background study interim final report prepared for FEMA and EPA contractors.
Similar indexed content
NYC-WTC_000301612
Draft report prepared for FEMA on WTC indoor air; authoring agency EPA Region 2.
Similar indexed content
COPC committee report with contributors from EPA, NYC DEP, and state agencies.
Similar indexed content