data sets for the three surfaces is recommended for the background concentration for porous surfaces. This value is 4,570 s/cm\

Wipe - There were 146 wipe samples collected, with 104 from residential areas and 42 from common spaces. The wipe samples were collected from hard surfaces including floors, walls, counters, and ceilings. These samples were analyzed for asbestos. The results from these analyses were quite variable between different surfaces and between different spaces. Overall, asbestos was detected about twice as frequently in the common areas (26%) than in the residential areas (13%). The results from the common areas had several very high concentrations reported due to detection limits being unusually high for several samples; ?(rhis might artificially increase the background concentrations and for this reason the common space data sets were not used for determining the background concentration.

Based on the residential data set, the mean concentration was higher in the ceiling samples, followed by the-floor samples, then the walls, and finally the counters. The UCLs for these surfaces were within an order of magnitude with the exception of the UCLTqf the ceiling, which was one order of magnitude higher. However, given that the pfimary goal is to estimate the background concentration for a residential space, it is recommended to use the entire residential data set, which includes ceilings, counters, floors, and walls to establish a background concentration for hard surfaces. The 95% UCL for this data set is 6,192 s/cm* and would be applicable for all hard surfacesjn a residential space.

6.2.2 MMVF Bulk Dust - There were twenty-four bulk dust samples collected and analyzed for MMVF. All of the samples were collected from the residential spaces. The results for the twenty-four samples were below the detection limit of 1%. As all of the samples were below the detection limit and the same detection limit was used throughout the Study, the UCL for MMVF in bu&'Hust could not be calculated because there was no standard deviation. The data suggests that background MMVF concentration in bulk dust is less than 1%, however, the confidence in this statement is limited due to the small sample size.

Air - There were sixty-two air samples collected, with forty-eight collected from residential spaces and fourteen collected from common areas. The frequency of detection for the common spaces (29%) was higher than the residentiaLspaces (2%), however the range of detections and means were very similar. The UCL for the combined data set is the same as the UCL for the residential data set. Given that the UCLs are the same, it is recommended to use the 95% UCL of 0.06 s/L or 0.00006 s/cc.

Wipe - There were 141 wipe samples collected, with ninety-nine collected from residential spaces and forty-two from common areas. The frequency of detection was similar between the residential (9%) and the common (11%) areas, as well as the range of detections and the mean for the wipe data set for each space. Each WORLD TRADE CENTER BACKGROUND STUDY 21

CITY_21MC1OO_OO4O53177

NYC-WTC_00032041 1

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000320411Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000418482

WTC background study interim final report prepared for FEMA and EPA contractors.

Similar indexed content

NYC-WTC_000348699

COPC committee report with contributors from EPA, NYC DEP, and state agencies.

Similar indexed content

Compare copies and versions →