WTC Background Study, EPA report draft

Machine-extracted title · confidence 28%

Oldraft report for World Trade Center background study prepared for FEMA, EPA Region 2.

NYC-WTC_000320385–000320529
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

residential areas differ, it is recommended to use the 95% UCL for the residential spaces of 0.0023 fZcc as the background value.

TEM AHERA - There was a higher percentage of detections in the common space areas (14%) than in the residential areas (4%) although the minimum and maximum detected concentrations were the same. In addition, the mean for each data set were similar. The four samples (two common area and two residential) that had detectable concentrations of asbestos were at the detection limit of 0.0004 s/cc. Since the frequency of detection was marginally different for the common space areas and the residential areas, it is recommended to use the 95% UCL for the residential spaces of 0.00024 free as the background value. fl '1 TEM PCMe - There was a higher percentage of detections in the common space are'as,(7%) than in the residential areas (4%) although the minimum and maximum detected concentrations were the same. In addition, the mean for each data set were almost equal. The three samples (two common area and one residential) that had detectable concentrations of asbestos were at the detection limit of 0.0004 s/cc. -TheUCL for the common areas (0.00029 s/cc) is marginally higher than the UCLforthe residential area (0.00024 s/cc). The combined data set yields a UCL that is the same value (0.00024 s/cc) as the residential UCL. Given that the residential areas and the combined data sets provide the same UCL, it is recommended to use the 95% UCL of 0.00024 free as the background value.

Microvacuum - There were 162 microvacuum samples collected, with 144 from residential areas and 18 from common spaces. The microvacuum samples were collected from porous materials, such as c^ets, area rugs and couches. These samples were analyzed for asbestos. The results from these analyses were quite variable between different surfaces and between the different spaces. One sample that was collected from a couch was determined to benn outlier due to the detection limit being roughly 30 times the detection limit of the other 161 samples which were analyzed. Summary statistic and UCLs wefe calculated with the outlier in the data set and again without the outlier m_the.data set. The results that were achieved without the outlier were more representative of the data. These results are reported below and in Tables 6-1 through 6-3.

Asbestos was detected more frequently in the common spaces (22%) and at higher concentrations (mean = 7,145 s/cm^) than in the residential spaces (4%). with a mean concentration of 2,234 s/cm7 In addition, the carpets in both spaces had greater mean concentrations than the other porous surfaces (i.e., couches, chairs, and drapes). The combined data sets were closer to the values from the residential spaces, although they were marginally higher. Since there was a large amount of variability between residential and common areas, the results from the residential spaces are recommended to be used for determining a background concentration, as these samples are more representative of what an apartment may contain. In addition, the porous surfaces that were sampled had UCLs that were within the same order of magnitude (i.e., carpet 8,084 s/cm^, couch 3,236 s/cm^, and drapes 6,149 s/cm'), therefore the 95% UCL for the residential spaces that combine the WORLD TRADE CENTER BACKGROUND STUDY 20

CITY_21MC100_0 04053176

NYC-WTC_000320410

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000320410Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000418482

WTC background study interim final report prepared for FEMA and EPA contractors.

Similar indexed content

NYC-WTC_000348699

COPC committee report with contributors from EPA, NYC DEP, and state agencies.

Similar indexed content

Compare copies and versions →