OCR status: ok · source: pdftotext

NYC £/11 Public Portal Document

hard surfaces including counters, floors and walls. The frequency of detection between the residential areas (49%) and the common areas (53%) for all of the wipe samples from each areas are similar, as are the range of detections and means, with the exception of the maximum detected concentration on the floor in the common area, which was about five times higher than the residential area. Although the data sets are very similar for both the spaces and surfaces, the inclusion of the maximum value for the floor in the common area of 49.2 pg/tf in the entire data for areas skews the data set and results in a UCL of 4.59 pg/ft^ which is a 97.5% UCL. Alternatively, if only the residential data set is used, a 95% UCL can be calculated, which provides a value of 1.78 pg/ft^ Either value wouldhe an acceptable background concentration for hard surfaces, however it is recomniended to use the 95% UCL value of 1.78 pg/ft^ that was calculated using only thprcsidential data set because of the marginal difference in the maximum detected concentration in the common areas and residential areas.

6.2.4 DioYiii Wipe - There were-H4 wipe samples collected, with 80 samples collected from residential areas and'34 samples collected from common areas. The samples were collected from hard surfaces including counters, floors, and walls. The samples were analyzed for dioxin and furan congeners and the results were reported in 2,3,7,8-tetracholorodibenzo-p-dioxin (TCDD) equivalents (i.e., TEQs). Any sample which was below the detection limit for any specific congener group was assigned a value of 'A of the detection limit before calculating the TEQ, thus for the statistical analysis the reported TEQ'was used without any further modifications. In addition, the TEQ.value that was used for estimating the background concentration was the_estimated maximum potential concentration (EMPC). The TEQ EMPC value uses data that indicated the detected presence of a compound above zero but did not meet all of QA/QC reporting level criteria.

The frequency of detection between the residential are'as -(23%) and the common areas (20%) were similar, as were the range of detections, means, and UCLs. The similarity between the data sets for the residential areas'and the common areas permits the use of the entire data set for estimating the background concentration. The 95% UCL calculated from the entire dioxin data set is 0.693 ng/m\ which can be used as an estimate of the background dioxin concentration on KW‘d‘'i surfaces.

6.2.5 PAH JL Wipe - There were 113 wipe samples collected, with 80 samples collected from residential areas and 33 samples collected from common areas. The samples were collected from hard surfaces including counters, floors, and walls. The samples were analyzed for 23 PAH compounds, of which seven of the compounds are used to calculate a toxicity equivalence factor (TEF). The analytical results indicate that none of the 23 PAH compounds were detected and the TEF for each sample would be equivalent to 290 pg/m^. The detection limit was the same for each sample that was analyzed, therefore a UCL cannot be calculated for the residential

WORLD TRADE CENTER BACKGROUND STUDY 23

CITY_21MC100_004053179

NYC-WTC_000320413

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000320413Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000418482

WTC background study interim final report prepared for FEMA and EPA contractors.

Similar indexed content

NYC-WTC_000348699

COPC committee report with contributors from EPA, NYC DEP, and state agencies.

Similar indexed content

Compare copies and versions →