the range of detections and the mean for the wipe data set for each space. Each space had wipe samples collected from hard surfaces including ceilings, counters, floors, and walls. The samples collected from the ceiling, counters, and walls in the common spaces were all below the detection limit and a UCL could not be calculated for these surfaces. All of the surfaces sampled from the residential areas had UCLs that were within a factor of three. Given that the residential data for the different surfaces were similar, as well as the data from the common areas, it is recommended to use the entire data set, which includes the residential and common spaces. This data set provides a 95% UCL of 52 s cm ’ as a background concentration for MMVF on hard surfaces.

6.2.3 Lead Bulk Dust - There were nine bulk dust samples collected from residential spaces and analyzed for lead. There were no bulk dust samples collected from the common areas. Lead was detected in all of the bulk samples ranging from 44 mg/kg to 242 mg/kg with a mean concentration of 126 mg/kg. The 95% UCL for this data set was calculated as 186 mg/kg. This UCL is recommended to be used as a background concentration for lead in bulk dust.

Air - There were forty-six air samples collected, with thirty-two samples collected from residential areas and fourteen collected from common areas. Only one sample, collected from a residential area, had a concentration of lead that was detectable and the lead concentration was equal to the detection limit. However, as the detection limit for the common areas and residential area samples varied slightly, a theoretical background concentration can be calculated for the common area because the range of detection limits permits a standard deviation to be calculated. The results indicate that the frequency of detection is similar between the residential areas (3%) and the common areas (0%), as well as the mean concentration. The UCL for each space is similar, 0.027 gm for common areas and 0.032 g/m’ for the residential area, therefore it is recommended to use the entire data set, which includes the common area and residential area, to calculate a background concentration. The 95% UCL for the entire data set, which should be considered the calculated background concentration, is 0.03 g/m\

Microvacuum - There were 144 microvacuum samples collected, with 114 collected in residential areas and 18 collected in common areas. The microvacuum samples were collected from porous materials including carpets, couches, chairs, and drapes. The frequency of detection for all of the microvacuum samples collected in the residential areas (8%) was similar to the samples collected in the common areas (6%), as were the ranges, mean, and calculated UCLs for the data sets for each space and each surface. Given the similarity between the data sets, both between spaces and between surfaces, it is recommended to use the entire microvacuum data set for estimating the background concentration of lead in porous surfaces. This yields a 95% UCL of 1.98 g/ffr for the background concentration of lead in porous surfaces.

WORLD TRADE CENTER BACKGROUND STUDY 25

CITY_21MC100_012423933

NYC-WTC_000418512

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000418512Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000320385

Oldraft report for World Trade Center background study prepared for FEMA, EPA Region 2.

Similar indexed content

Compare copies and versions →