NYC 9/11 Public Portal Document UU I iu*' UI • UI h.AA

I. Introduction/SumnuLry

Glcmar Corp., Asbestos Testing and Consulting, was contracted by Newmark & Company, Real Estate, Inc.,to perform PCM Air Quality Testing on various floors of the building at 40 Worth Street, New York, NY.

Testing was performed to determine the levels of fibers that were present in the building as a result of the massive dust created by the claps of the World Trade Center Buildings on September 11, 2001.

Testing took place on September 25, 2001.

Glomar Corp. Technician, Mr. Sean Murray, was the on-site Air Monitoring Technician.

All air samples were collected by Glomar Corp and analyzed by •Scientific Labs, New York, NY, a New York State approved environmental Testing Laboratory. All samples were analyzed utilizing Phase Contrast Microscopy (PCH) and had fiber counts of well below 0.01 fibers per cubic centimeters (f/cc).

II. Adr Monitoring Criteria, Methods and Analy»i»

Air monitoring complied with Part 56 of Title 12 Sub-Part SG-l?, Air Sampling Monitoring and Analysis of the Official Compilation of Codes, Rules and Regulations of the State of New York, Sub­ Part 56-17. Air Sampling Monitoring and Analysis requirements establishes schedules and methods that were followed by Glomar personnel. Analysis of A.ir Monitoring samples shall use (at a minimum.) Phase Contrast Microscopy (PCM) or Transmission Electron Microscopy (TEM) using standards administered by the National Institute for Occupational Safety & Health (NIOSH) Method 7400 (PCM) a:>d Method 7402 (TEM) . Also followed is the New York State Departm-'.-nt of Health Environmental Laboratory Approval Program (SLAP,) Item's 236-273. PCM analysis gives an index of Airborne fibers .Ln the work place and TEM analysis gives an index of Asbeston Airborne Fibers in the work place.

App ;ndix A for Air Sanq}!* Locations and Anslysis

1 ~

cr ‘c /

CITY_21MC100_0 04067190

NYC-WTC_000320041

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000320041Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →