SILICA. CRYSTALLINE, by XRD: METHOD 7500, Issue 3, dated 15 January 1998 - Page 6 of 8

m = slope of calibration graph, counts/pg

P: T = -R In T/(1 - T”) = absorption correction factor (Table 1) sin (©AgVsin (QJ fAg/(average gg) = transmittance of sample normalized silver peak intensity from sample average tg = normalized silver peak intensity from media blanks (average of six values)

EVALUATION OF METHOD:

This method is based on P&CAM 259 which was collaboratively tested [1]. The testing included a ruggedizationstep to test the effects of the use of muffle furnace or plasma asher (but not the use of THF), shipment of samples, ashing time, and ultrasonication time. None of these factors was found to have an effect. The method was shown to have no bias when referenced to the Talvitie spectrophotometric method [10] and when all standards and samples were Min-U-Sil 5. The relative standard deviations ^Sfor intralaboratory, total measurement and overall (including sampling) variability are:

Measurement Precision, S-’ Intralaboratory: 50 to 200 pg - 0.08 [1] 20 pg - 0.20 [5] 10 pg -0.28 [9] Total (intra-and interlaboratory): 50 to 200 pg -0.17[1]

Overall (Sampling & Measurement) Precisions,p Total (intra- and interlaboratory): 50 to 200 pg - 0.29 [1]

REFERENCES:

[1] Anderson CC [9183]. Collaborative tests of two methods for determining free silica in airborne dust. U.S. Department of Health and Human Services, Publ. (NIOSH) 83-124. [2] NIOSH [1983]. User check, UBTL, NIOSH Sequence #4121-M (unpublished) [3] NIOSH [1974]. Criteria for a RecommendedStandard: Occupational Exposure to Crystalline Silica. U.S. Department of Health, Education, and Welfare, Publ. (NIOSH) 75-120. [4] NIOSH [1979]. Silica, crystalline: Method P&CAM 259. In: Taylor DG, ed., NIOSH Manual of Analytical Methods, 2nd ed., Vol. 5., Cincinnati, OH: U.S. Department of Health, Education, and Welfare, Publ. (NIOSH) 79-141. [5] Ibid, Vol. 3, S315. U.S. Department of Health, Education, and Welfare, Publ. (NIOSH) 77-157-C (1977). [6] NIOSH [1977]. Documentation of the NIOSH Validation Tests. S315, U.S. Department of Health, Education, and Welfare, Publ. (NIOSH) 77-185. [7] NIOSH [1977]. Silica (XRD): Method P&CAM 109. In: Taylor DG, ed., NIOSH Manual of Analytical Methods, 2nd ed.. Vol. 1. Cincinnati. OH: U.S. Department of Health, Education, and Welfare, Publ. (NIOSH) 77-157-A. [8] Bumsted HE [1973]. Determinationof alpha-quartz in the respirable portion of airborne particles by X-ray diffraction. Am Ind Hyg Assoc. J34:150. [9] Peters ET [1976]. Evaluation Of the NIOSH X-ray diffraction method for the determination of free silica in respirable dust. Final Report, NIOSH Contract CDC-99-74-51. [10] Talvitie NA [1964]. Determination of free silica: gravimetric and spectrophotometric procedures applicable to airborne and settled dust. Am Ind Hyg Assoc 325:169-178. [11] Kupel RE, Kinser RE, Mauer PA [1968]. Separation and analysis of the less than 10-micron fractions of industrial dusts. Am Ind Hyg Assoc 329:364. [12] Talvitie NA[1951]. Determination ofquartzin presenceofsilicatesusingphosphoricacid. AnalChem 23 (4). [13] Williams DD [1959]. Direct quantitative diffractometric analysis. Anal ChenSf:1841. [14] Abell MT, Dollberg DD, Crable JV[1981]. Quantitative analysis of dust samples from occupational environments using computer automated X-ray diffraction. Advances in X-Ray Analys&f:37. [15] Abell MT, Dollberg DD, Lange BA, Hornung RW, Haartz JC [1981]. Absorption corrections in X-ray

NIOSH Manual of Analytical Methods (NMAM), Fourth Edition

CITY_21MC100_011095726

NYC-WTC_000319958

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000319958Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →