SILICA. CRYSTALLINE, by XRD: METHOD 7500, Issue 3, dated 15 January 1998 - Page 7 of 8

diffraction dust analyses: procedures employing silver filters. Electron Microscopy and X-Ray Applications, V. 2, p. 115, Ann Arbor Science Publishers, Inc. [16] Dollberg DD. Abell MT, Lange BA [1980]. Occupational health analytical chemistry; quantitation using x-ray powder diffraction. ACS Symposium Series, No. 120, 43. [17] Altree-WilliamsS, Lee J, Mezin NV. Qualitative X-ray diffractometry on respirable dust collected on nuclepore filters. Ann Occup Health Hyg20;109. [18] Leroux J, Powers C [1970]. Direct X-ray diffraction quantitative analysis of quartz in industrial dust films deposited on silver membrane filters. Occup Health Re2f:26.

METHOD REVISED BY:

Charles Lorberau. M. T. Abell, and D. D, Dollberg. Ph.D.. NIOSH/DPSE.

APPENDIX: INTERFERENCES

Interferences include barite, micas (muscovite, biotite), potash, feldspars (microcline, plagioclase), montmorillonite, sillimanite, zircon, graphite, iron carbide, clinoferrosillite, wollastonite, sanidine, leucite, orthoclase, and lead sulfide.

The patterns for three forms of aluminum phosphate [JCPDS 10-423,11-500, 20-44] are practically identical to those of quartz, cristobalite and tridymite, respectively. The quartz secondary and cristobalite primary peaks are close; cristobalite secondary peak is overlapped by a quartz peak; tridymite if present in sufficient quantity, w/ill interfere with all of the main (primary, secondary and tertiary) quartz and cristobalite peaks. Silver chloride, if present on the silver filter, interferes slightly with the primary quartz peak. Many of these interferences occur in the presence of quartz; however, in a study of samples collected in 11 different industries, Altree-William [17] found no significant interferences.

The presence of elements such as iron can result in appreciable X-ray fluorescence which leads to high background intensity. A diffracted-beam monochromator will minimize this problem.

If calcite is present, loss of quartz will occur when samples are ashed in a muffle furnace. See SAMPLE PREPARATION (step 5.b) for procedure to remove calcite.

If interferences with the primary silica peak are present, use a less sensitive peak. When overlaps are not severe, a smaller receiving slitor chromium radiation may be used; however, a new calibration curve will be necessary.

NIOSH Manual of Analytical Methods (NMAM), Fourth Edition

CITY_21MC1OO_O11O95727

NYC-WTC_000319959

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000319959Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →