Material Science Division Operating Procedures for Silica Analysis : MSD 0700 Jansooo

1.0 The procedures outlined herein are intended for the identification and quantification of Silica by X-Ray Diffraction. Including NIOSH 7500 and OSHA - ID142 Methods.

1.1 Terms & Definitions

Silica: Term used to denote ot-Quartz, Cristobalite or Tridymite. XRD: X-Ray Diffraction

2.0 Equipment Requirements

XRD: X-Ray Diffractometer (theta-2-theta) Tools: Forceps, cleaning tissue, alcohol or other cleaning agent, 0.45um Silver membrane filters, fritted glass filtration apparatus, petri dishes {50mm), XRD sample holders. Reagents: Quartz, Cristobalite and Tridymite 2-Propanol, reagent grade Tetrahydrofuran (THF) 25% Hydrochloric acid (HCL) Particle free, deionized water

2.1 Equipment Calibrations 2.1.1 The XRD is calibrated daily using Silicon powder to determine the peak centroid alignment. 2.1.2 The XRD is calibrated daily using a-Quartz to determine the resolution of the peaks.

3.0 Preparation of Air Sampling Cassettes:

3.1 The exterior of the cassette is wiped to remove loose dirt and dust. 3.2 One end plug is removed and the cassette is placed into a dessicator for one hour. 3.3 The dried filter is weighted on an analytical balance capable of 0.0001 gm sensitivity. 3.4 The filter is placed into a 20ml scintillation vial and filled with roughly 15mls of THF. 3.5 Place the sample in an ultrasonic bath for ten minutes. 3.6 Filter the suspension through a 0.45um silver membrane filter using the fritted glass filtration unit.

3

CITY_21MC1OO_O1O22O834

NYC-WTC_000338497

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000338497Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →