NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 8 pages

Silica, crystalline by XRD method details

Machine-extracted title · confidence 42%

Laboratory method sheet for crystalline silica analysis by XRD (Quartz, cristobalite, tridymite).

NYC-WTC_000319953–000319960
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

SILICA, CRYSTALLINE, by XRD 7500

SiOj MW: 60.08 CAS: 14808-60-7 (quartz) RTECS: VV7330000 (quartz) 14464-46-1 (cristobalite) VV7325000 (cristobalite) 15468-32-3 (tridymite) VV7335000 (tridymite)

METHOD: 7500, Issue 3 EVALUATION: FULL Issue 1: 15 August 1990 Issues: 15 January 1998

OSHA : quartz (respirable) 10 mg/m7(%SiO2+2); PROPERTIES; solid; d 2.65 g/cm’ @ 0 ’C; crystalline cristobalite and tridymite (respirable) % the above transformations: quartz to tridymite NIOSH: 0.05 mg/m’; carcinogen @ 867 °C; tridymite to cristobalite @ 1470 ACGIH: quartz (respirable) 0.1 mg/m’ °C: a-quartz to ii-quartz @ 573 °C cristobalite (respirable) 0.05 mg/m’ tridymite (respirable) 0.05 mg/m’

SYNONYMS; free crystalline silica: silicon dioxide

SAMPLING MEASUREMENT

SAMPLER: CYCLONE + FILTER TECHNIQUE: X-RAY POWDER DIFFRACTION (10-mm nylon cyclone, Higgins-Dewell (HD) cyclone, or aluminum cyclone + ANALYTE: crystalline SiOj 5-pm PVC membrane ASH: muffle furnace or RF plasma asher FLOW RATE: nylon cyclone: 1.7L/min, or dissolve in tetrahydrofuran HD cyclone: 2.2 L/min; aluminum cyclone: 2.5 L/min REDEPOSIT: on 0.45-(jm Ag membrane filter

VOL-MIN: 400 L XRD: Cu target X-ray tube, graphite -MAX: 1000 L monochromator Optimize for intensity: 1 ° slit SHIPMENT: routine Slow step scan, 0.02°/10 sec Integrated intensity with background SAMPLE subtraction STABILITY: stable CALIBRATION: suspensions of silica in 2-propanol BLANKS: 2 to 10 per set (See step 12.g.) RANGE: 0.02 to 2 mg SiOj per sample [2] BULK SAMPLE: high-volume or settled dust; to identify interferences ESTIMATED LOD: 0.005 mg SiOj per sample [2]

PRECISION P,); 0.08 @ 0.05 to 0.2 mg per sample [1] ACCURACY

RANGE STUDIED; 25to2500pg/mMl] (800-L sample)

BIAS: none known

OVERALL PRECISION C,t): 0.09 (50 to 200 pg) [1]

ACCURACY: ±18%

APPLICABILITY; The working range is 0.025 to 2.5 mg/m’ for an 800-L air sample.

INTERFERENCES: Micas, potash, feldspars, zircon, graphite, and aluminosilicates. See APPENDIX.

OTHER METHODS: This is similar to the method in the Criteria Document [3] and P&CAM 259 [4] which has been collaboratively tested (2). This method is similar, except for sample collection, to S315 [5,6]. Method P&CAM 109 [7,8,9], which incorporates an internal standard, has been dropped. Colorimetry (10) is an alternate measurement procedure (used in Method 7601), as is IR spectrometry (Methods 7602 and 7603).

NIOSH Manual of Analytical Methods (NMAM), Fourth Edition

CITY_21MC100_011095721

NYC-WTC_000319953

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000319953Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →