SILICA, CRYSTALLINE, by XRD: METHOD 7500, Issue 3, dated 15 January 1998 - Page 2 of 8

REAGENTS: EQUIPMENT;

1. Silica Standards. 1. Sampler: a. Quartz* (SRMs 1878 and 2679) and a. Filter: Polyvinyl chloride (PVC) filter, 37- Cristobalite’ (SRM 1879), available from mm, 5.0-pm pore size supported with Standard Reference Materials backup pad in a two-piece, 37-mm cassette Program, Rm. 204, Bldg. 202, National filter holder (preferably, conductive) held Institute of Standards and Technology together by tape or cellulose shrink band. (NIST), Gaithersburg, MD 20899. NOTE: Check each newlot of PVC filters b. Tridymite*, available from NIOSH, by analyzing one or more by this DPSE, ARDB, 4676 Columbia Pkwy., method. For example, Gelman Cincinnati, OH 45226. VM-1 filters (all lots) were found to 2. 2-Propanol, reagent grade. be unacceptable because of high 3. Desiccant. ash and background. If THF is 4. Glue or tape for securing Ag filters to XRD used, check for complete holders. dissolution by dissolving a blank 5. Optional; tetrahydrofuran (THF)* (if LTA or PVC filter and following through muffle furnace are unavailable). steps 5c through 8. 6. Optional (if calcite present): 25% v/v b. Cyclone: 10-mm nylon, Higgins-Dewell concentrated hydrochloric acid (ACS (HD), Aluminum (Al), or equivalent. reagent grade) in distilled water and 2. Area air sampler; PVC membrane filter, 37- 25-mm filters of PVC or cellulose ester mm diameter, 5-pm pore size; three-piece with pore size of 1 pm or less. filter cassette. 3. Sampling pumps with flexible connecting tubing, capable of the following flow rates; * See SPECIAL PRECAUTIONS. nylon cyclone, 1.7 L/min; HD cyclone, 2.2 L/min; Al cyclone, 2.5 L/min; and bulk sampler, 3 L/min. 4. Silver membrane filters, 25-mm diameter, 0.45-pm pore size. 5. X-ray powder diffractometer (XRD) equipped with copper target X-ray tube, graphite monochromator, and scintillation detector. 6. Reference specimen (mica, Arkansas stone, or other stable standard) for data normalization. 7. Low-temperature radio-frequency plasma asher (LTA) or muffle furnace, or ultrasonic bath (i150 W), for filter preparation. 8. Vacuum filtration assembly and side-arm vacuum flask with a 25-mm filter holder. 9. Sieve, 10-pm. for wet sieving. 10. Analytical balance (0.001 mg); magnetic stirrer with thermally insulated top; ultrasonic bath or probe; volumetric pipettes and flasks; Pyrex crucibles with covers (muffle furnace); 40-mL wide-mouth or 50-mL centrifuge tubes (THF method); desiccator; reagent bottles with ground glass stoppers; drying oven; polyethylene wash bottle.

SPECIAL PRECAUTIONS: Avoid inhaling silica dust [3]. THF isextremely flammable and should be used in a fume hood.

NIOSH Manual of Analytical Methods (NMAM), Fourth Edition

CITY_21MC100_008986691

NYC-WTC_000338316

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000338316Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →