NYC-WTC_000319786
Laboratory guidance on analyzing non-friable asbestos-containing materials and PLM alignment.
8 shared non-person entities · 1 shared topics · similarity 0.988
machine-extracted · confidence unavailable · Check page ↗EPA/DOE manual describing identification of asbestos in non-friable bulk materials.
NYC-WTC_000319762–000319785OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
FROM US EPA/OERR (TUE) 1 2. 1 1 ■ 01 9:21/ST. 9 : 1 1/NO. 486 1 202483 P 15
ENVIRONMENTAL LABORATORY APPROVAL PROGRAM CERTIFICATION MANUAL
SUBJECT DATE PAGE ITEM NO.
Transmission Electron Microscope Method for 3/1/97 14 of 34 198.4 Identifying and Quantitating Asbestos in Non- Friable Organically Bound Bulk Samples
SomecharaGteristicsof asbestosare qiven inTable I. Atleastfourfibers of— asbestos in each sample must be positiveiy identified by each of the criteria required ontheanalysis sheet: ; '5 11.Morphology. CKlX^Electrdixdiffracti^^ data. At least four fibers must be positively identified by electron diffraction. 5.1.2.1. Chrysotile. Minimum requirements for positive identification of chrysotile are: 5.1.2.1.1. Correct (5.3 A) layer-line (row) spacing. 5.1.2.1.2. Correct orientation of 002, 020, 110, 130 and 200 points or streaks. 5.1.2.2. Amphibole. 5.1.2.2.1. Correct (5.3 A) layer-line (row) spacing or 5.1.2.2.2. Zone-axis measurements that match one of the five asbestos amphiboles. 5.1.3. Elemental composition from energy-dispersive x-ray spectrometer. 5.1.3.1. Chrysotile. (Optional). 5.1.3.2. Amphiboles. Elements critical to the identification of a specific type must be detected at ratios consistent with that type's elemental composition as determined through k-factor calculations. 5 2 Quantitation. ^Matrix losses must be gravimetrically tracked at each preparation step (Section 4.2 through 4.3). Estimates of asbestos percentage versus the percentage of remaining insoluble inorganic matrix material must be made for both of the TEM grid preparations except when final asbestos
CITY_21MC100_003050110
NYC-WTC_000319775
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000319786
Laboratory guidance on analyzing non-friable asbestos-containing materials and PLM alignment.
8 shared non-person entities · 1 shared topics · similarity 0.988
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000250730
EPA memo documenting issues with asbestos testing standards post-WTC collapse.
5 shared non-person entities · 1 shared topics · similarity 0.941
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000363857
Letter/report about bulk dust/debris sampling on building setbacks for Insignia ESG at a NYC building.
2 shared non-person entities · 1 shared topics · similarity 0.957
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000342629
Summary of bulk and TEM sampling with lab analysis and quality control.
9 shared non-person entities · 1 shared topics · similarity 0.943
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000390391
Bulk sampling of debris from the roof to determine asbestos content.
2 shared non-person entities · 1 shared topics · similarity 0.942
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000409508
Documentation of sampling and transfer of asbestos samples from Building 200 per EPA guidelines.
9 shared non-person entities · 1 shared topics · similarity 0.939
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000367022
TEM asbestos analysis report for 11/15/01 sample 01-2200, 99 Battery Place.
5 shared non-person entities · 1 shared topics · similarity 0.937
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000357500
Summary of analytical results for asbestos by PLM for a NYC site, Sept 2001.
7 shared non-person entities · 1 shared topics · similarity 0.937
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000219925
Document excerpt of 40 CFR Part 763 Appendix A detailing mandatory and non-mandatory analytical methods for asbestos in schools as of January 2002.
9 shared non-person entities · 1 shared topics · similarity 0.937
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000357497
PLM analytical results for asbestos at 3 World Financial Center Floors 3-26.
7 shared non-person entities · 1 shared topics · similarity 0.937
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000438164
EPA SOP excerpts and references for asbestos validation and inspections.
9 shared non-person entities · 1 shared topics · similarity 0.937
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000435395
Part 763 Subpart text related to asbestos standards and testing definitions.
9 shared non-person entities · 1 shared topics · similarity 0.937
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000318678
Background study draft on asbestos in schools related to WTC, March 2003.
Similarity score 0.953 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000318556
Information sheet on asbestos design and analysis standard D5755, undated revision notes.
Similarity score 0.951 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000219925
Document excerpt of 40 CFR Part 763 Appendix A detailing mandatory and non-mandatory analytical methods for asbestos in schools as of January 2002.
Similarity score 0.946 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000301400
HSDB compilation entry on asbestos manufacturing, use, and properties.
Similarity score 0.945 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000338306
Partial evaluation of asbestos by method 7402 with fiber-concentration guidance.
Similarity score 0.942 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000219925
Document excerpt of 40 CFR Part 763 Appendix A detailing mandatory and non-mandatory analytical methods for asbestos in schools as of January 2002.
Similarity score 0.941 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000319786
Laboratory guidance on analyzing non-friable asbestos-containing materials and PLM alignment.
Similar indexed content
NYC-WTC_000363857
Letter/report about bulk dust/debris sampling on building setbacks for Insignia ESG at a NYC building.
Similar indexed content
Summary of bulk and TEM sampling with lab analysis and quality control.
Similar indexed content
NYC-WTC_000390391
Bulk sampling of debris from the roof to determine asbestos content.
Similar indexed content
NYC-WTC_000250730
EPA memo documenting issues with asbestos testing standards post-WTC collapse.
Similar indexed content