ASBESTOS - HSDB - Hazardous Substances Data Bank Page 2 of 3
element composition, maintains the surface composition, and preserves the crystalline
structure. Further, investigation of electrokinetic properties of these dusts by electrophoretic
quasi-elastic light scattering is described. The small size dispersity of these samples facilitates
use of this technique for the determination of the apparent electrokinetic charge and estimations
of surface charge density at ionic strengths below physiological. It is suggested that analyses of
the type described here be an integral part of studies of the fibrogenic, immunologic, or
toxicologic properties of such minerals. /Chrysotile asbestos/ ay CO
4. A field study was conducted to measure asbestos fiber concentrations during brake repair for
mechanics in the Federal Republic of Germany. In addition to asbestos air sampling, 210
occupational histories describing working conditions under which brake maintenance is carried
out were evaluated. Ninety dust concentration measurements in 76 service stations with static
and personal samplers during brake maintenance operations. Sampling times varied from less
than 3 min to more than 1 hr depending on the duration of the work operation. Samples were
analyzed by phase contrast microscopy and scanning transmission electron microscopy. Fiber
concentrations during brake service operations were 0.1X104-6/cu m (0.1 fiber per cc) on
average. Average fiber dosages (fiber concentration X sampling time) ranged from 4X10-1-6
fiber/cu m/min for dry brushing and grinding to lOXlO-l-6 fibers/cu m/min for machine
grinding. Electron microscopy of brake drum dust indicated very high concentrations of short
fibers; fibers with lengths > 5 um constituted less than 1% of all the chrysotile fibers counted.
5. BOTH TRANSMISSION & SCANNING ELECTRON MICROSCOPY ... USED TO
IDENTIFY & QUANTIFY ... FIBERS.... MICROCHEMICAL ANALYSIS (ELECTRON
MICROPROBE ANALYSIS) ... . /ASBESTOS FIBERS/ 03
6. METHODS OF CONFIRMING ASBESTOS CAN INCLUDE OPTICAL TESTING USING
POLARIZED LIGHT, FIRST ORDER RED OR OTHER RETARDATION PLATES,
ANGLES OF EXTINCTION, DISPERSION STAINING. BULK SAMPLES MAY BE
ANALYZED BY X-RAY DIFFRACTION OR IR ABSORPTION OF DIFFERENTIAL
THERMAL ANALYSIS. CD
7. TRANSMISSION ELECTRON MICROSCOPY ... PARTICAL MORPHOLOGY CAN BE
ACCURATELY OBSERVED & ELECTRON DIFFRACTION PATTERNS ARE
DISPLAYED. NIOSH (NATIONAL INSTITUTE FOR OCCUPATIONAL SAFETY &
HEALTH), "RE-EXAMINATION & UPDATE OF INFORMATION ON THE HEALTH
EFFECTS OF OCCUPATIONAL EXPOSURE TO ASBESTOS," WASHINGTON DC
(1977).
8. NIOSH 7402: Analyte: asbestos fibers; Matrix: air: Technique: Transmission electron
microscopy; Range: 100-1300 fibers/sq mm filter area; Precision: 0.28 when 65% of fibers are
asbestos; 0.20 when adjusted fiber count is applied to PCM count; Est limit of detection: 1
confirmed asbestos fiber above 95% of expected mean blank value; Interferences: Non-
asbestiform amphiboles may interfere in the transmission electron microscopy analysis if the
individual particles have aspect ratios greater than 3; 1. These interferences can only be
eliminated by quantitative zone axis electron diffraction analysis. NIOSH method 7400 (phase
contrast microscopy) is designed for use with this method. CO
9. NIOSH 7400: Analyte: asbestos fibers; Matrix: air: Technique: Light microscopy, phase
contrast; Range: 100-1300 fibers/sq mm filter area; Precision: 0.10 to 0.12 (based on OSHA
regulations for rule A); Est limit of detection: 7 fibers/sq mm filter area. This method gives an
index of airborne fibers in workplace atmospheres. Phase contrast microscopy will not
differentiate between asbestos & other fibers; use this method in conjunction with electron
microscopy (eg, Method 7402) for positive identification. Fibers < about 0.25 um diameter will
not be detected by this method. Any other airborne fiber may interfere. Chain-like particles
may appear fibrous. High levels of non fibrous dust particles may obscure fibers in the field of
http://www.tomescps.com/DATA/HS/HS511J.htm 1/4/2002