9.0 MONITORING AND ANALYSIS METHODS
Sampling Procedures:
1. SAMPLE IS COLLECTED WITH A HIGH VOLUME SAMPLER ON MICROSORB AN
PAPER. THE PAPER IS DISSOLVED IN BENZENE. CD
2. NIOSH 7402: Analyte: asbestos fibers; Matrix: air; Sampler: filter (0.8-1.2 um cellulose ester
membrane, 25 mm diameter; conductive cassette); Flow rate: 0.5-16 1/min; Vol: min: 4001 at
0.1 fiber/ml; max: 10,000 1; Sample stability: stable. Shipment is routine (securely packed to
reduce shock). CO
3. NIOSH 7400: Analyte: Fibers (including asbestos fibers); Matrix: air; Sampler: filter (0.8-1.2
um cellulose ester membrane, 25 mm diameter; conductive cowl on cassette); Flow rate: 0.5 to
16 1/min; Minimum vol: 400 1 at 0.1 fiber/ml; Maximum vol: 10,000 1; Stability: stable.
Shipment is routine (securely packed to reduce shock). to
Analytical Laboratory Methods:
1. JEFFREY MINE & COALING MINE CHRYSOTILE, 2 ASBESTOS SAMPLES PREPARED
FOR EXPERIMENTAL HEALTH SCIENCES, & THE UNION INTERNATIONALE
CONTRE LE CANCER B CHRYSOTILE REFERENCE SAMPLE HAVE BEEN
CHARACTERIZED DI THE AEROSOLIZED STATE USING GRAVIMETRIC
MEASUREMENTS, LIGHT MICROSCOPY, & X-RAY ENERGY SPECTROMETRY. IS
2. Light microscopy, with phase contrast at 400X; feature examined: morphology, limit of
resolution about 0.5 um; dispersion staining: feature examined: refractive index and
morphology, skilled operators can distinguish asbestos fibers. Limit of resolution about 0.5 um
sq m; X-ray difraction: crystal structure; infrared spectroscopy: characteristic absorption bands;
atomic absorption: elemental composition; neutron activation: elemental composition;
emission spectroscopy: elemental composition; thermal analysis (TGA & DTA): weight loss on
heating due to dehydroxylation; scanning electron microscopy with microprobe: surface
topology of the fiber and elemental analysis, most scanning electron microscopes have a
theoretical resolution limit of about 10.0-20.0 nm. Background can give interference;
transmission electron microscopy with microprobes, feature examined: shape outline, electron
diffraction and elemental analysis, resolution limit down to 0.40 nm. Transfer to grid can lead
to statistical errors in counting. Si* tO
3. A method for cryogenically grinding and separating (by size) fibrogenic minerals in the I
micron size range is described and verified for chrysotile asbestos, quartz, forsterite (an
olivine), and tantalum with a battery of analytical tests. Through use of energy dispersive X-ray
photoelectron spectroscopy, and X-ray diffraction analysis it is shown that the grinding and
separation procedure described does not alter the mineral composition, preserves the trace