NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 100 pages

ASB Part 763 SOP excerpt, EPA 763 rules

Machine-extracted title · confidence 32%

EPA Part 763 asbestos SOP excerpt with subparts and scope.

NYC-WTC_000449399–000449498
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Pt. 763. Subpt. E. App. E 40 CFR Ch. I (7-1-00 Edition) 8.5 A) minerals (see Table 2—2). The X-ray dif­ 2. Dry at 100 °C for 2 hr; cool in a desic­ fraction equipment should be optimized for cator. intensity. A slow scanning speed of 1° 20/min 3. Weigh accurately to the nearest 0.01 iiig. is recommended for adequate resolution. Use 4. Samples shown by PLM to contain large of a sample spinner is recommended. amounts of cellulosic or other organic mate­ 4. Submit all samples that exhibit diffrac­ rials, gypsum, or carbonates, should be sub­ tion peaks in the diagnostic regions for mitted to appropriate matrix reduction pro­ asbestiform minerals to a full qualitative cedures described in Sections 2.7.2.1.2 and XRD scan (5°-6CP 26; l°2e/min) to verify initial 2.7.2.1.3. After ashing and/or acid treatment, peak assignments and to identify potential repeat the drying and weighing procedures matrix interferences when subsequent quan­ described above, and determine the percent titative analysis is to be performed. weight loss; L. 5. Compare the sample XRD pattern with 5. Quantitatively transfer an accurately standard reference powder diffraction pat­ weighed amount (50—100 mg) of the sample to terns (i.e., JCPDS powder diffraction data-’or a 1—L volumetric flask with approximately those of other well-characterized reference 200 mL isopropanol to which 3 to 4 drops of materials). Principal lattice spacings of surfactant have been added. asbestiform minerals are given in Table 2—2; 6. Ultrasonicate for 10 min at a power den­ common constituents of bulk insulation and sity of approximately 0.1 W/mL, to disperse wall materials are listed in Table 2—3. the sample material. 7. Dilute to volume with isopropanol. 2.7.2.2.2 DeTecTion of minor or trace consTiiu- 8. Place flask on a magnetic stirring plate. ents— Routine screening of bulk materials Stir. by XRD may fail to detect small concentra­ 9. Place a silver membrane filter on the fil­ tions (<5 percent) of asbestos. The limits of tration apparatus, apply a vacuum, and at­ detection will, in general, be improved if ma­ tach the reservoir. Release the vacuum and trix absorption effects are minimized, and if add several milliliters of isopropanol to the the sample particle size is reduced to the op­ reservoir. Vigorously hand shake the asbes­ timal 1 to 10 pm range, provided that the tos suspension and immediately withdraw an crystal lattice is not degraded in the milling aliquot from the center of the suspension so process. Therefore, in those instances where that total sample weight, Wt, on the filter confirmation of the presence of an will be approximately 1 mg. Do not adjust asbestiform mineral at very low levels is re­ the volume in the pipet by expelling part of quired, or where a negative result from ini­ the suspension; if more than the desired ali­ tial screening of the bulk material by XRD quot is withdrawn, discard the aliquot and (see Section 2.7.2.2.1) is in conflict with pre­ resume the procedure with a clean pipet. vious PLM results, it may be desirable to Transfer the aliquot to the reservoir. Filter prepare the sample as described for quan­ rapidly under vacuum. Do not wash the res­ titative analysis (see Section 2.7.2.3) and ervoir walls. Leave the filter apparatus step-scan over appropriate 20 ranges of se­ under vacuum until dry. Remove the res­ lected diagnostic peaks (Table 2—2). Accurate ervoir, release the vacuum, and remove the transfer of the sample to the silver mem­ filter with forceps. (Note: Water-soluble ma­ brane filter is not necessary unless subse­ trix interferences such as gypsum may be re­ quent quantitative analysis is to be per­ moved at this time by careful washing of the formed. filtrate with distilled water. Extreme care 2.7.2.3 Quantitative Analysis should be taken not to disturb the sample.) 10. Attach the filter to a flat holder with a The proposed method for quantitation of suitable adhesive and place on the diffrac­ asbestos in bulk samples is a modification of tometer. Use of a sample spinner is rec­ the NIOSH-recommended thin-layer method ommended. for chrysotile in air.^A thick-layer or bulk 11. For each asbestos mineral to be method involving pelletizing the sample may quantitated select a reflection (or reflec­ be used for semiquantitative anal­ tions) that has been shown to be free from ysis L-®ho we ver, this method requires the ad­ interferences by prior PLM or qualitative dition of an internal standard, use of a spe­ XRD analysis and that can be used unambig­ cially fabricated sample press, and relatively uously as an index of the amount of material large amounts of standard reference mate­ present in the sample (see Table 2—2). rials. Additional research is required to 12. Analyze the selected diagnostic reflec- evaluate the comparability of thin- and tion(s) by step scanning in increments of thick-layer methods for quantitative asbes­ 0.02° 20 for an appropriate fixed time and in­ tos analysis. tegrating the counts. (A fixed count scan For quantitative analysis by thin-layer may be used alternatively; however, the methods, the following procedure is rec­ method chosen should be used consistently ommended: for all samples and standards.) An appro­ 1. Mill and size all or a substantial rep­ priate scanning interval should be selected resentative portion of the sample as outlined for each peak, and background corrections in Section 2.7.2.1.1. made. For a fixed time scan, measure the

736

CITY_21MC100_011980863

NYC-WTC_000449486

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000449486Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000442707

Pallet of Part 763 asbestos-related standard references and definitions.

Similar indexed content

Compare copies and versions →