Bulk asbestos analysis method update, lab manual

Machine-extracted title · confidence 48%

EPA/DOE manual describing identification of asbestos in non-friable bulk materials.

NYC-WTC_000319762–000319785
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

FROM US EPA/OERR (TUE) 1 2. 1 I ’ 01 9 ; 20/ST, 9 : 1 1/NO. 4861 202483 P 14

ENVIRONMENTAL LABORATORY APPROVAL PROGRAM CERTIFICATION MANUAL

SUBJECT DATE PAGE ITEM NO.

Transmission Electron Microscope Method for 3/1/97 13 of 34 198.4 Identifying and Quantitating Asbestos in Non- Friable Organically Bound Bulk Samples

grids. To avoid overlooking these heavier fibers, sample residue will have to be examined by PLM. A section (4-9 mm^) of residue should be detached from the polycarbonate filter and "placed in a dfdplefof no=lT605*high-dispersi6rriiq^^ a clean microscope slide. This residue should be disaggregated by a shearing rubout procedure or similar technique. A coverslip is placed on the preparation and more refractive-index liquid is added at the coverslip edge as necessary. 5. Sample Analysis. Each of the prepared grids should be scanned initially at low (~3000) magnification to evaluate the suitability of the preparation. Most grid openings should be covered with intact carbon film and particle distribution should cover 10 to 50% of the grid area. Heavier coverings will tend to make the materials opaque to the electron beam and will make identification and quantitation difficult. Unsuitable preparations must be discarded and additional preparations should be made to compensate for the problems detected on the original preparations, e.g., place a smaller or more dilute subsample on the grid if initial preparations were too heavily loaded. The analyst should also make a presumptive determination of asbestos type(s) present at low magnification before increasing magnification to 10,000 to 20,000 for positive identification. This should be performed on fibers protruding from and representative of large bundles. Finally, the analyst should , return to low magnification to estimate the amount of asbestos versus nonasbestos on the entire grid. This procedure must be repeated on the second grid preparation. I

i 5.1. identification. Although this method specifies criteria for positive identification of asbestos, it is not intended as a tutorial in asbestos identification. It is expected that analysts using this method are competent in the identification of asbestos by TEM and can refer to appropriate resource texts for assistance in identification. w \ i

I CITY_21MC100_003050109

NYC-WTC_000319774

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000319774Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000342629

Summary of bulk and TEM sampling with lab analysis and quality control.

Similar indexed content

Compare copies and versions →