NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 24 pages

Bulk asbestos analysis method update, lab manual

Machine-extracted title · confidence 48%

EPA/DOE manual describing identification of asbestos in non-friable bulk materials.

NYC-WTC_000319762–000319785
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

FROM US EPA/OERR (TUE) 12. 11’01 9 : 1 5/ST. 9 : 1 1/NO. 486 1 202483 P 13

ENVIRONMENTAL LABORATORY APPROVAL PROGRAM CERTIFICATION MANUAL

SUBJECT DATE PAGE ITEM NO.

Transmission Electron Microscope Method for 3/1/97 12 of 34 198.4 Identifying and Quantitating Asbestos in Non- Friable Organically Bound Bulk Samples

4.3. Acid Digestion. Grind residue in crucible with 0.5 mL 0.1-pm-filtered distilled water and add 2-5 mL concentrated HCI. After 15 minutes, dilute with O.Vprn- ' ''' I filtered distilled water and pour into filtration apparatus holding a fared 0.4-pm polycarbonate filter and apply vacuum. Rinse the crucible a second time and pour this into the filtration apparatus and rinse down the sides of the apparatus. When filtration is complete, transfer filter and residue carefully to a clean, fared plastic petri dish and allow filter to dry to stable mass under a heat lamp. Weigh filter and petri dish and calculate percent mineral carbonate loss. If the residue mass is less than 1 % of the subsample's original mass, analysis may be terminated and the sample reported as a non-ACM (Section 6.3.2.1). 4.4. Grid Preparation. At least two grid preparations must be made from the residue on the filter. Excise a section (50-200 mm^, depending on residue thickness) of the polycarbonate filter and transfer to a disposable plastic beaker. Add approximately 5 mL of filtered ethanol and treat in ultrasonic bath for one minute. Place a carbon-film TEM grid in tweezers under a heat lamp and, while the ultrasonic bath is still operating, pipette approximately 3 pL of the suspension onto the TEM grid. (Ensure that the pipette tip’s orifice is large enough to accommodate large fibers.) Allow each grid to dry under the heat lamp. A thin carbon coat may be evaporated onto each grid to minimize material loss. Transfer grids to labeled petri dishes or grid box until analysis. 4,5. Slide Preparation. This step will not be necessary for samples that contain more than 1% asbestos as determined by TEM or for samples previously analyzed by the optional PLM method (Section 4.2 of Item 196.1). Ina few instances, large amphibole fibers at low concentrations may not have been transferred to TEM \

1 CITY_21MC100_003050108

NYC-WTC_000319773

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000319773Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000342629

Summary of bulk and TEM sampling with lab analysis and quality control.

Similar indexed content

Compare copies and versions →