NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 64 pages

EPA background report, WTC air contaminants, 1987

Machine-extracted title · confidence 29%

Background report on asbestos and related contaminants for WTC environment, 1987.

NYC-WTC_000318755–000318818
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

15870 Federal Register / Vol. 52. No. 83 / Thursday, April 30* 1987 / Proposed Rules

TABLE IV — Summary of DQOs This table summarizes the data quality objectives from the performance of this method in terms of precision, accuracy. completeness, representativeness, and comparability. These objectives are assured by the periodic control checks and references checks listed here and described in the text of the method. (ii Conformance Unit Operation OC Check_____ • Frequency______ Exnectation Sampling materials Sealed blank 1 per I/O site 95% Sample procedures Field blanks 2 per I/O site 95% Pump calibration Before and after each field series 90% . Sample receiving Review of receiving report Each sample 95% complete Sample custody Review of chain-of-custody record, Each sample 95% complete Sample preparation Supplies and reagents On receipt Meet specs, or reject 1 ■ Grid opening size 20 openingsZ20 grids/lot 100% of 1000 or 1 opening/sample

I ■' Special clean area monitoring After cleaning or service Meet specs, or reclean Laboratory blank 1 per prep series or 10% Meet specs dr reanalyze series

I Plasma ashcr blank Sample recovery check 1 per 20 samples 1 per 20 samples 75% 75% .

Multiple preps (3 per sample) Each sample One with cover of 15 1 complete grid sqs.

Sample analysis System check Each operator Each day I , Alignment check Each operator Each day Magnification calibration with low Each month or after service , 95% and high standards SAED calibration by gold standard Weekly 95% EDS calibration by copper line Daily 95%

Performance check Laboratory blank (measure of cleanliness) Prep 1 per series ot 1()% Meet specs ot read 1 per 25 samples reanalyze series Replicate counting (measure of precision) 1 per 1(X) samples 1.5 X Poisson Std. Dev. Duplicate analysis (measure of reproducibility) 1 per 100 samples 2 X Poisson Std. Dev. Known samples of typical materials Training and for com­ 100% (working standards) parison with unknowns

IJ Analysis of NBS SRM 1876 and/or RM 8410 (measure of accuracy and comparability) 1 per analyst per year 1.5 X Poisson Std. Dev.

Data entry review (data validation and measure Each sample 95% of completeness)

1 Calculations and Hand calculation of automated 1 per 100 samples 85% data reduction data reduction procedure or independent recalculation of hand-calculated data Site evaluation Abatement area versus ambient When abatement area is >0.02 f/cc 100% I , 8IUJNG CODE 8560-50-0

t

NYC-WTC_000318806

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000318806Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →