NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 64 pages

EPA background report, WTC air contaminants, 1987

Machine-extracted title · confidence 29%

Background report on asbestos and related contaminants for WTC environment, 1987.

NYC-WTC_000318755–000318818
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Federal Register / Vol. 52, No. 83 / Thursday, April 30, 1987 / Proposed Rules 15869

VIII. Quality Control/Quality 4. Insure that the samples are stored 17. Provide laboratory blanks with Assurance Procedures [Data Quality in a secure and representative location. each sample batch. Maintain a moving Indicators) 5. Insure that mechanical vibrations average of these results. If there are from the pump will be minimized. more than 3 fibers per 10 grid openings Monitoring the environment for 6. Insure that a constant flow of the system will be checked for possible airborne asbestos requires the use of negative pressure is delivered by the sensitive sampling and analysis sources of contamination. pump by installing a damping chamber 18. Check for recovery of asbestos procedures. Because the test is sensitive, if necessary. it may be influenced by a variety of from cellulose ester filters submitted to 7. Open a loaded cassette plasma asher treatment by including a factors. These include the supplies used momentarily at one of the indoor in the sampling operation, the known asbestos particulate sample with sampling sites when sampling is every 25th numbered sample. performance of the sampling, the initiated. This sample will serve as an preparation of the grid from the filter Recoveries of 75 percent or greater are indoor field blank. acceptable. and the actual examination of this grid 8. Open a loaded cassette in the microscope. Each of these unit 19. Check for asbestos carryover in momentarily at one of the outdoor the plasma asher by including a blank operations must produce a product of sampling sites when sampling is defined quality if the analytical result is alongside the positive control sample. initiated. This sample will serve as an to be a reliable and meaningful test outdoor field blank. 20. Perform a systems check on the result. Accordingly, a series of control 9. Carry a sealed blank into the field transmission electron microscope each checks and reference standards are with each sample series. Do not open time it is used. performed along with the sample this cassette in the field. 21. Make periodic performance checks u analysis as indicators that the materials 10. Perform a leak check of the of magnification selected area electron used are adequate and the operations sampling system at each indoor and diffraction and energy dispersive X-ray are within acceptable limits. In this way outdoor sampling site by activating the systems as set forth in Table IV. the quality of the data is defined and the pump with the closed sampling cassette 22. Insure qualified operator results are of known value. These in line. Any flow indicates a leak which performance by evaluation of replicate checks and tests also provide timely and must be eliminated before initiating the counting, duplicate analysis and specific warning of any problems which sampling operation. standard sample comparisons as set might develop within the sampling and 11. Insure that the sampler will be forth in Table IV. analysis operations. A description of turned upright before interrupting the these quality control/quality assurance . pump flow.. 23. Validate all data entries. procedures is summarized in Table IV 24. Recalculate a percentage of all 12. Check that all samples are clearly computations arid automatic data and the text below. labeled and that all pertinent 1. Prescreen the loaded cassette reduction steps as specified in Table IV. information has been enclosed before 25. Use the outdoor control samples i. collection filters to assure that they do not contain concentrations of asbestos transfer of the samples to the laboratory. for comparison with the abatement area I,- . which may interfere with the analysis of samples for clearance approval if the 13. When the samples arrive at the abatement area samples exceed the the sample. A filter blank average of laboratory, check the samples and less than 0.5 asbestos fibers per 10 grid permissible limits. documentation for completeness and openings is acceptable for this method. requirements before initiating the The outline of quality control

r } 2, Calibrate sampling pumps and their analysis. flow indicators over the range of their intended use with a recognized standard. Assemble the sampling 14. Check all laboratory reagents and supplies for acceptable asbestos background levels. procedures presented above is viewed as the minimal required to assure the data . * ■ . for - e - produced quality , clearance . , testing of an asbestos abated area. ■

system with a representative filter—not 15. Conduct all sample preparations in Additional information may be gained by other control fests. Specifics on those F the filter which will be used in a clean room environment monitored by sampling—before and after the sampling laboratory blanks and special testing control procedures and options operation. after cleaning or service in the area. available for environmental testing can 3. Record all calibration information 10. Prepare multiple grids of each be obtained by consulting references 6, with the data to be used on a standard sample for possible duplicate count 7. and 11. sampling form. comparison. BILLING CODE 8580-50-M

i I

NYC-WTC_000318805

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000318805Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →