Pt. 763, Subpt. E, App. A 40 CFR Ch. I (7-1-00 Edition)

TABLE III—SUMMARY OF LABORATORY DATA QUALITY OBJECTIVES

Conformance Unit Operation OC Check Frequency Expectation

Sample receiving Review of receiving report Each sample 95% complete Sample custody Review of chain-of-custody record Each sample 95% complcic Sample preparauwi Supplies and reagents On receipt Meet specs, or reject Grid opening size 20 openings/20 grids/lot 100% of 1000 or 1 opening/samplc Special clean area monitoring After cleaning or service Meet specs or reclean Laboratory blank 1 per prep senes or 10% Meet specs, or reanalyze series Plasma etch blank 1 per 20 samples 75% Multiple preps (3 per sample) Each sample One with cover of 15 complete grid sqs. Sample analysis System check Ea:hday Each day Alignment check Each day Each day Magnincation calibration with low and high Each month or after service 95% standards ED calibration by gold standard Weekly 95% EDS calibration by copper line Daily 95% Performance check Laboraiory blank (measure of cleanliness) Prep 1 per scries or 10% Meet specs or re^ 1 per 25 samples reanalyze series Replicate counting (measure of precision) I per 100 samples 1.5 X Poisson Std. Dev. Duplicate analysis (measure of reproducibility) I per 100 samples 2 X Poisson Std. Dev Known samples of typical materials Training and for com­ 100% (woriong standards) parison with unknowns Analysis of NBS SRM 1876 and/or RM 8410 1 per analyst per year 1.5 X Poisson Sid. Dev, (measure of accuracy and comparability) Data entry review (data validation and measure Each sample 95% of completeness) Record and verify ID electron difhaction pattern 1 per 5 samples 80% accuracy ofstnicture Calculations and Hand calculation of automated data reduction 1 per 100 samples 85% data reduction procedure or independent recakulaiion of hand- calculated data

1. When the samples arrive at the labora­ 5. Provide laboratory blanks with each tory. check the samples and documentation sample batch. Maintain a cumulative aver­ for completeness and requirements before age of these results. If this average is greater initiating the analysis. than 53 f/mm2 per 10 200-mesh grid openings, 2. Check all laboratory reagents and sup­ check the system for possible sources of con­ plies for acceptable asbestos background lev­ tamination. els. 6. Check for recovery of asbestos from cel­ 3. Conduct all sample preparation in a lulose ester filters submitted to plasma clean room environment monitored by lab­ asher. oratory blanks and special testing after 7. Check for asbestos carryover in the plas­ cleaning or servicing the room. ma asher by including a blank alongside the 4. Prepare multiple grids of each sample. positive control sample.

702

NYC-WTC_000390011

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000390011Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →