NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 9 pages

ASME Data: designator D5755, 1995 revision

Machine-extracted title · confidence 27%

Information sheet on asbestos design and analysis standard D5755, undated revision notes.

NYC-WTC_000318556–000318564
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document NO.780 P.4/d □ S7SS conuminaiion before'Uking cassettes'into a clean prepara­ tion area. , ' I /approximate ■ /45 OECREE 10.2 Perform sample preparation t'n a clean, facility; that I / ANCLE . has a separate work a.-ea from both the bulk and air sample ■ 1" TO 1-J/2' preparation areas, OR 25 MM TO 37WM ilu iit: ir 10.3 Initial specimen prsparatibn shall take place jn a • clean HEPA filtered negative pressure hood to avoid'any possible oohtaminatidn of the laboratory or personnel, or I both, by the potentially large number of asbestos structures, 11 li'i 1/<" DIAMETER in an asbestos-containing dust sample. Cleanliness of the TUBING preparation area hoi^s is measured by the cumulative process blank concenirations (see Section 11). . 10.4 All sample preparation steps ,10.4.1 through 10.4.6 FJQ, t 'Saampio ot ©a Vu^ng Mosalo shall take place in the dust preparatio.n area inside a HEPA hood. sample area of 100 cm* is vacuumed until there is no visible 10.4.1 Remove the upper plug.from the sample cassette , dust or particulates .matter remaining. Perform s rainimum ■ and carefully introduw approximaicly 10 mL solution of a 50/50 mixture of particle-free watsJ’ and reagent alcohol Into of two orthogonal passes on the surface within a minimum the cassette using a plastic wash baric {7.44). If the plugged of 2 min of sampling time. Avoid scraping or abrading the . nozzle was left attached to the cassette, then remove the.plug surface being sampled. (Do not sample any debris or dust and intfoduce the watcr/alcohol solution into the cassette particles greater than I mm in diameter (sec 4.2).) Smaller or through the tubing, and then remove the tubing, ifat is larger areas can be* Sampled, if needed. For example, some visibly-clean, , surfaces of interest । may have a smaller area than 100 cm^. Less dusty surfaceslcmay require vacuuming of large? areas. 10,4.2 Replace the upper plug or the sample cap and Urtlike air samples, the overloading of the cassettes with dust lightly shake the dustlsuspension by hand for 3 s. - will not be a problem. As defined in 3.2.5, only dust shall be 10.4.3 Remove the entire cap of th? cassette aad pour the collected for this analysis, ■ suspension through ai 1.0 by I.O mm opening screen (7.46) .8.8 At the end ofi sample collection, invert the cassette so into a pre<lcaned 200 raL glass specimen battle (7.9). All visible that the nozzle inlet faces up before shutting off the power to .rinsed traces of the sample contained in the cassette sh^ll be the pump. The nozzle is then sealed with a cassette end-plug through the screen into the specimen bottle with a and the.cassette/nozzle uped or appropriately packaged to plastic wash bottle containing the 50/50 solution of particle- prevent separation, of the nozzle and cassette assembly, A free water and .alcohol. Repeat this'procedure two additional second option is ihfc removal of the nozzle'ftom the cassette, .u for a• total of times u thfee u washings. v Next, • rinse the nozzle . two . then pluggingof th«iicassetts and shipment of the nozzle (also sp^imen tottle plugged al both ends) sealed in a.separate closeable plastic **}** 50/50 mixture of water and akohol. Typically, the bag. A_third optiohi'is placing the nozzle inside the cassette for shipment, the nbzzk isjlwavi saved and rinsed because 75 mL. Discard the 10 by 1.0 mm sareen 8nd_ bnng the ^iSSnt from of soluuon m ih^pccmien bottle up to the 100 mL TT lere.io the iriside vv^s of thelu^nB. “S?? f u *** waur only. • 8.5 Check that all samples are dearly labeled, that all dwt i^jusi the pH of the suspensim to 3 to 4 usii^ a sampling information sheets are completed, and that all lOiO % solution of aceuc acid. Use pH paper for testing. pertinent information has been enclosed, in accordance with V’® whin 24 h to avoid problems associ- laboraiory quality ;eontrol practices, before transfer of the ai^with lienal and fungal ^wth. . samples to the laboratory. Include an unused cassette and either a ^sposabie plastic fihWion unit or a - - ---------------------- glass filtenng unit (7 14) for mtration of ahquots of the 8.10 Wipe off thfe exterior, surface .of the cassettes with sus^ion, The sbibty of an individual filtration uan to disposable wet towels (baby wipes) prior to packing for produce a uailonn. disinbutioa may be tested the .shipment. filtration of a colored'paniculate suspension such as diluted . India ink (suspension of carbon black). o 10.4,5,1 Ifa disposable plastic filtration unit is used, then ' . rL- J L- I . I I I <_ unwrap a new dispo^ble plastic filter ftihoel unit (either 25 9,1 Ship duist samples to w analytical laboratory la a or 47 mni diameiar) and remove the tape around the b^ of coataioer. Wt separate from any bulk or air samples the funnel and' discard the top filter The cottes must,'^ tightly scaled and packed in a saaien^ supplied . with the apparatus, retaining the coarse free of fiters or to axini^ coaUmi- polypropylene support pad in place. Assemble the unit with aauon. Plastic bubble jack is probably the moat appro- gxlapter and a properly sized neoprene Kopper; and pnaie matenaJ for this purpose. attach the funnel to'the 1000 mL side-arm •vacuum' flask (?.15). Place a 5.0 mil pore size MCE (backing filter) on the BO, Sample PifepnWrioa support pad. Wet it with a few mL of particle-free wat^r and 10.1 Under a negative flow HEPA hood (7.5), carefully place aa MCE (7.16) or PC filter (s0,22 jim pore size) (7,17; wet-wipe the exterior of the cassettes to remove any posible on top of the backing filter. Apply a vacuum (7,36), ensuring 4

CITY_21MC100_011092778

NYC-WTC_000318559

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000318559Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →