NYC-WTC_000318755
Background report on asbestos and related contaminants for WTC environment, 1987.
27 shared non-person entities · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗Background study draft on asbestos in schools related to WTC, March 2003.
NYC-WTC_000318678–000318754OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Federal Register / Vol. 52, No, 210 / Friday, October 30, 1987 / Rules and Regulations 41877
k. At the conclusion of sampling, turn aggressive sampling conditions to entering the abatement site. If makeup the cassette upward before stopping the dislodge any remaining dust. air entering the abatement site is drawn flow to minimize possible particle loss. 1. Equipment used in aggressive from another area of the building which If the sampling is resumed, restart the sampling such as a leaf blower and/or is outside of the abatement area, place flow before reorienting the cassette fan should be properly cleaned and the pumps in the building, pumps should downward. Note the condition of the decontaminated before use. be placed out of doors located near the filter at the conclusion of sampling. ii. Air filtration units shall remain on building and away from any 1. Double check to see that all during the air monitoring period. obstructions that may influence wind information has been recorded on the iii. Prior to air monitoring, floors, patterns. If construction is in progress data collection forms and that the ceiling and walls shall be swept with the immediately outside the enclosure, it cassette is securely closed and exhaust of a minimum one (1) may be necessary to select another appropriately identified using a horsepower leaf blower. ambient site. Samples should be waterproof label. Protect cassettes in iv. Stationary fans are placed in representative of any air entering the individual clean resealed polyethylene locations which will not interfere with work site. bags. Bags are to be used for storing air monitoring equipment. Fan air is b. Locate the ambient samplers at cassette caps when they are removed directed toward the ceiling. One fan least 3 ft apart and protect them from for sampling purposes. Caps and plugs shall be used for each 10,000 ft ’ of adverse weather conditions. should only be removed or replaced worksite. c. Sample same volume of air as using clean hands or clean disposable V. Monitoring of an abatement work samples taken inside the abatement site. area with high-volume pumps and the plastic gloves. use of circulating fans will require C. Sample Shipment m. Do not change containers if electrical power. Electrical outlets in the portions of these filters are taken for 1. Ship bulk samples in a separate abatement area may be used if other purposes. container from air samples. Bulk avaflable. If no such outlets are 8. Minimum sample number per site. A samples and air samples delivered to available, the equipment must be minimum of 13 samples are to be the analytical laboratory in the same supplied with electricity by the use of collected for each testing consisting of container shall be rejected. extension cords and strip plug units. All the following: electrical power supply equipment of 2. Select a rigid shipping container • a. A minimum of five samples per this type must be approved Underwriter and pack the cassettes upright in a abatement area. Laboratory equipment that has not been noncontaminating nonfibrous medium b. A minimum of five samples per modified. All wiring must be grounded. such as a bubble pack. The use of ambient area positioned at locations Ground fault interrupters should be resealable polyethylene bags may help representative of the air entering the used. Extreme care must be taken to to prevent jostling of individual abatement site. clean up any residual water and ensure cassettes. c. Two field blanks are to be taken by that electrical equipment does not 3. Avoid using expanded polystyrene removing the cap for not more than 30 become wet while operational. because of its static charge potential. sec and replacing it at the time of vi. Low volume pumps may be Also avoid using particle-based sampling before sampling is initiated at carefully wrapped in 6-mil polyethylene packaging materials because of possible the following places: to insulate the pump from the air. High contamination. i. Near the entrance to each ambient volume pumps cannot be sealed in this 4. Include a shipping bill and a area. manner since the heat of the motor may detailed listing of samples shipped, their ii. At one of the ambient sites. melt the plastic. The pump exhausts descriptions and all identifying numbers (Note: Do not leave the blank open during should be kept free. or marks, sampling data, shipper’s name, the sampling period.) vii. If recleaning is necessary, removal and contact information. For each of this equipment from the work area sample set, designate which are the d. A sealed blank is to be carried with must be handled with care. It is not ambient samples, which are the each sample set. This representative possible to completely decontaminate abatement area samples, which are the cassette is not to be opened in -the field. the pump motor and parts since these field blanks, and which is the sealed 7. Abatement area sampling. areas cannot be wetted. To minimize blank if sequential analysis is to be a. Conduct final clearance sampling any problems in this area, all equipment performed. only after the primary containment such as fans and pumps should be 5. Hand-carry samples to the barriers have been removed; the carefully wet wiped prior to removal laboratory in an upright position if abatement area has been thoroughly from the abatement area. Wrapping and possible; otherwise choose that mode of dried: and, it has passed visual sealing low volume pumps in 6-mil transportation least likely to jar the inspection tests by qualified personnel. polyethylene will provide easier samples in transit. (See Reference 1 of Unit III.L.) decontamination of this equipment. Use 6. Address the package to the b. Containment barriers over of clean water and disposable wipes laboratory sample coordinator by name windows, doors, and air passageways should be available for this purpose. when known and alert him or her of the must remain in place until the TEM e. Pump flow rale equal to or greater package description, shipment mode, clearance sampling and analysis is than 1 L/min or less than 10 L/min may and anticipated arrival as part of the completed and results meet clearance be used for 25 mm cassettes. The larger chain of custody and sample tracking test criteria. The final plastic barrier cassette diameters may have procedures. This will also help the remains in place for the sampling period. comparably increased flow. laboratory schedule timely analysis for c. Select sampling sites in the f. Sample a volume of air sufficient to the samples when they are received. abatement area on a random basis to ensure the minimum quantitation limits. provide unbiased and representative D. Quality Control/Quality Assurance (See Tab!eIofUnilIll.B.5.j.) samples. 8. Ambient sampling. Procedures (Data Quality Indicators) d. After the area has passed a , a. Position ambient samplers al Monitoring the environment for thorough visual inspection, use locations representative of the air airborne asbestos requires the use of
NYC-WTC_000318730
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000318755
Background report on asbestos and related contaminants for WTC environment, 1987.
27 shared non-person entities · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000449399
EPA Part 763 asbestos SOP excerpt with subparts and scope.
27 shared non-person entities · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000451982
Chain-of-custody and SOP excerpt focusing on asbestos validation and PCB spiking.
27 shared non-person entities · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000434918
Continuation of the asbestos validation SOP text with definitions and scope.
27 shared non-person entities · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000445234
EPA Part 763 subpart I excerpt regarding asbestos, testing parameters and definitions.
27 shared non-person entities · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000452898
Chain-of-custody excerpt referencing Part 763 asbestos procedures and compliance.
27 shared non-person entities · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000433711
Page from Part 763 asbestos standard; references to testing and enforcement sections.
27 shared non-person entities · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000445985
Chain-of-custody excerpt referencing Part 763 sections and regulatory definitions.
27 shared non-person entities · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000435395
Part 763 Subpart text related to asbestos standards and testing definitions.
27 shared non-person entities · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000438164
EPA SOP excerpts and references for asbestos validation and inspections.
27 shared non-person entities · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000442707
Pallet of Part 763 asbestos-related standard references and definitions.
27 shared non-person entities · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000434667
Environmental protection document detailing Part 763 asbestos definitions and related sections.
27 shared non-person entities · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000452898
Chain-of-custody excerpt referencing Part 763 asbestos procedures and compliance.
Similarity score 0.980 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000434918
Continuation of the asbestos validation SOP text with definitions and scope.
Similarity score 0.980 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000445985
Chain-of-custody excerpt referencing Part 763 sections and regulatory definitions.
Similarity score 0.980 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000449399
EPA Part 763 asbestos SOP excerpt with subparts and scope.
Similarity score 0.980 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000443893
Chain-of-custody appendix with Part 763 asbestos standards and definitions.
Similarity score 0.980 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000442707
Pallet of Part 763 asbestos-related standard references and definitions.
Similarity score 0.980 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000318755
Background report on asbestos and related contaminants for WTC environment, 1987.
Similar indexed content
NYC-WTC_000449399
EPA Part 763 asbestos SOP excerpt with subparts and scope.
Similar indexed content
NYC-WTC_000451982
Chain-of-custody and SOP excerpt focusing on asbestos validation and PCB spiking.
Similar indexed content
NYC-WTC_000434918
Continuation of the asbestos validation SOP text with definitions and scope.
Similar indexed content
NYC-WTC_000445234
EPA Part 763 subpart I excerpt regarding asbestos, testing parameters and definitions.
Similar indexed content