NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 77 pages

Background study draft for WTC asbestos, 2003

Machine-extracted title · confidence 37%

Background study draft on asbestos in schools related to WTC, March 2003.

NYC-WTC_000318678–000318754
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

41878 Federal Register / Vol. 52, No. 210 / Friday. October 30, 1967 / Rules and Regulations

sensitive sampling and analysis sampling—before and after the sampling E. Sample Receiving procedures. Because the lest is sensitive, operation. it may be influenced by a variety of '3. Record all calibration information 1. Designate one individual as sample factors. These Include the supplies used with the data to be used on a standard coordinator at the laboratory. While that in the sampling operation, the sampling form. individual will normally be available to performance of the sampling, the 4. Ensure that the samples are stored receive samples, the coordinator may preparation of the grid from the filter in a secure and representative location. train and supervise others in receiving and the actual examinaUon of this grid procedures for those times when he/^e 5. Ensure that mechanical calibrations in the microscope. Each of these unit from the pump will be minimized to is not available. operations must produce a product of prevent transferral of vibration to the 2. Adhere to the following procedures defined quality if the analytical result is cassette. to ensure both the continued chain-of- to be a reliable and meaningful test 6. Ensure that a continuous smooth custody and the accountability of all result. Accordingly, a series of control flow of negative pressure is delivered by samples passing through the laboratory: checks and reference standards is the pump by installing a damping a. Note the condition of the shipping performed along with the sample chamber if necessary. package and data written on it upon analysis as indicators that the materials 7. Open a loaded cassette receipt used are adequate and the operations momentarily at one of the indoor are within acceptable limits. In this way. sampling sites when sampling is b. Retain all bills of lading or shipping the quality of the data is defined, and slips to document the shipper and the results are of known value. These initiated. This sample will serve as an delivery time. checks and tests also provide timely and indoor field blank. c. Examine the chain-of-custody seal, specific warning of any problems which 8. Open a loaded cassette if any. and the package for its integrity. might develop within the sampling and momentarily at one of the outdoor d. If there has been a break in the seal analysis operations. A description of sampling sites when sampling is or substantive damage to the package. these quality control/quality assurance initiated. This sample will serve as an the sample coordinator shall procedures is summarized in the text ■ outdoor field blanL immediately notify the shipper and a below. 9. Carry a sealed blank into the field responsible laboratory manager before 1. Prescreen the loaded cassette with each sample series. Do not open any action is taken to unpack the collection filters to assure that they do this cassette in the field. shipment. not contain concentrations of asbestos 10, Perform a leak check of the e. Packages with significant damage which may interfere with the analysis of sampling system at each indoor and shall be accepted only by the the sample. A filter blank average of outdoor sampling site by activating the responsible laboratory manager after less than 18 s/mm* in an area of 0.057 pump with the closed sampling cassette in line. Any flow indicates a leak which discussions with the client. mm’ (nominally 10 200-mesh grid must be eliminated before initiating the 3. Unwrap the shipment in a clean, openings} and a maximum of 53 s/mm’ for that same area for any single sampling operation. uncluttered facility. The sample preparation is acceptable for this 11. Ensure that the sampler is turned coordinator or his or her designee will method- upright before interrupting the pump record the contents, including a . - 2. Calibrate sampling pumps and their flow. description of each item and all flow indicators over the range of their 12. Check that all samples are clearly identifying numbers or marks, A Sample Intended use with a recognized labeled and that all pertinent Receiving Form to document this standard- Assemble the sampling information has been enclosed before information is attached for use when- system with a representative filter—not transfer-of the"samples to the necessary. (See the following Figure 3.) the filter which will be used in -- laboratory. BtLUNO COOE tSSO-SO-M

i

NYC-WTC_000318731

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000318731Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →