TEM/ASTM dust method label, 5755, 2001

Machine-extracted title · confidence 32%

ATC TEM dust method practice document referencing AHERA/ASTM 5755.

NYC-WTC_000363392–000363403
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document 12/11/2001 17:06 FAI 212 353 8306 ATC ®007

D5755

conuraination before raking cassettes into a clean prepara­ I tion area. /approximate 10.2 Perform sample preparation in a clean facility that /as decree / angle has a separate work area from both the bulk and air sample 1" TO 1-1/2" preparation areas, OR 10.3 Initial specimen preparation shall take place in a 25 MM TO 37mm clean HEPA filtered negative pressure hood to avoid any possible contamination of the laboratory or personnel, or both, by the potentially large number of asbestos structures 1/^" DIAMETER in an asbestos-containing dust sample. Cleanliness of the TUBING preparation area hoods is measured by the cumulative process blank concentrations (see Section 11). 10.4 All sample preparation steps 10.4.1 through 10.4.6 .■f -' FIG. 1 Exampl* of the Tubing Nozzle shall take place in the dust preparation area inside a HEPA hood. 10.4.1 Remove the upper plug from the sample cassette sample area of 100 cm’ is vacuumed until there is no visible and carefully introduce approximately 10 mL solution of a dust or particulates matter remaining. Perform a minimum 50/50 mixture of particle-free water and reagent alcohol into of two orthogonal passes on the surface within a minimum the cassette using a plastic wash bottle (7.44). If the plugged of 2 min of sampling time. Avoid scraping or abrading the nozzle was left attached to the cassette, then remove the plug surface being sampled. (Do not sample any debris or dust and introduce the water/alcohol solution into the cassette panicles greater than l mm in diameter (see 4.2).) Smaller or through the tubing, and then remove the tubing, if it is larger areas can be sampled, if needed. For example, some suifaccs of interest may have a smaller area than 100 cm’. visibly clean. 10.4.2 Replace the upper plug or the sample cap and Less dusty surfaces may require vacuuming of larger areas. lightly shake the dust suspension by hand for 3 s. Unlike air samples, the overloading of the cassettes with dust 10.4.3 Remove the entire cap of the cassette and pour the will not be a problem. As defined in 3.2.5, Only dust shall be suspension through a 1.0 by 1.0 mm opening screen (7.46) collected for tlus analysis. into a pre-cleaned 200 mL glass specimen bottle (7.9). AU 8.8 At the end of sample collection, invert the cassette so visible traces of the sample contained in the cassette shall be that the nozzle inlet faces up before shutting off the power to . the pump. The nozzle is then sealed with a cassette end-plug rinsed through the screen into the spedmen bottle with a nd the cassette/nozzle taped or appropriately packaged to plastic wash bottle containing the 50/50 solution of particle- prevent separation of the nozzle and cassette assembly. A free water and alcohol. Repeat this procedure two additional second option is the removal of the nozzle from the cassette, times fora total of three washings. Next, rinse the nozzle two then plugging of the cassette and shipment of the nozzle (also or three times through the screen into the specimen battle plugged at both ends) sealed in a separate closeable plastic with the 50/50 mixture of water and alcohol. Typically, the hag. A third option is placing the nozzle inside the cassette total amount of the 50/50 mixture used in the rinse is 50 to for shipment The nozzle is always saved and rinsed because 75 mL. Discard the 1,0 by 1.0 mm screen and bring the a significant percentage of the dust drawn from a lightly volume of solution in the specimen bottle up to tiie 100 mL loaded surface may adhere to the inside walls of the tubing. mark on the side of the bottle with particle-free water only. 8.9 Check drat all samples are dearly labeled, that all dim 10.4.4 Adjust the pH of the suspension to 3 to 4 using a sampling information sheets are completed, and dial all 10.0 % solution of acetic add. Use pH paper for testing. pertinent information has been enclosed, in accordance with Filter the suspension within 24 h to avoid problems associ­ laboratory quality control practices, before transfer of the ated with bacterial and fungal growth. samples to the laboratory. Include an unused cassette and 10.4.5 Use either a disposable plastic filtration unit or a nozzle as a Add Mank. glass filtering unit (7.14) for filtration of aliquots of the 8.10 Wipe off the exterior surface of the cassettes with suspension. The ability of an individual filtration unit to disposable wet towels (baby wipes) prior to packaging for produce a uniform distribution may be tested by the shipment. filtration of a colored particulate suspension such as diluted India ink (suspension of carbon blade). 9.. Sample Shipment 10.4.5.1 If a disposable plastic filtration unit is uiW, then unwrap a new disposable plastic filter funnel unit (either 25 9.1 Ship dust samples to an analytical laboratory in a or 47 mm diameter) and remove the tape around the base of sealed container, but separate from any bulk or air samples. the funnel. Remove the funnel and discard the top filter The cassettes must be tightly sealed and packed in a material supplied with the apparatus, retaining the coarse free of fibers or dust to minimize the potential for contami­ polypropylene support pad in place. Assemble the unit with nation. Plastic "bubble pack" is prol^y the most appro­ the adapter and a property sized neoprene stopper, and priate material for this purpose. attach the funnel to the 1000 mL side-arm vacuum flask (7.15). Place a 5.0 ^m pore size MCE (backing filter) on the to. Sample Priiiaradon support pad. Wet it with a few mL of particle-free water and ' ' 10.1 Under a negative flow HEPA hood (7.5), carefully place an MCE (7.16) or PC filter (s0.Z2 p.m pore size) (7.17) wci-wipe the exterior of the cassettes to remove any possible on top of the backing filter. Apply a vacuum (7.36), ensuring

4

CITY_21MC100_002847941

NYC-WTC_000363395

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000363395Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →