NYC-WTC_000389978
Policy language on clean areas, HEPA filtration, and sampling expectations for asbestos work.
10 shared non-person entities · 1 shared topics · similarity 0.980
machine-extracted · confidence unavailable · Check page ↗ATC TEM dust method practice document referencing AHERA/ASTM 5755.
NYC-WTC_000363392–000363403OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document 12/11/2001 17:06 FAI 212 353 8306 ATC ®008
^Sll) D 5755 that the filters are centered and pulled flat without air 10.4,11 Apply vacuum to the flask and draw the mixture bubbles. Any irregularities on the filter surface requires the through the filter. discard of that filter. After the filter has been seated properly, 10.4.12 Discard the pipette. replace the funnel and rescal it with the tape. Return the 10.4.13 Disassemble the filtering unit and carefully re flask to atmospheric pressure. move the sample filter with fine tweezers (7.11). Place the 10.4.5.2 If a glass filtration unit is used, place a 5 pm pore completed sample filter panicle side up, into a prccleaned, size MCE (backing filter) on the glass frit surface. Wet the labeled, disposable, plastic petri dish (7.48) or other similar filter with particle-free water, and place an MCE or PC filter container. (sO.22 gm pore size) on top of the backing filter. Apply a 10.4.14 In order to ensure that an optimally-loaded filter vacuum, ensuring that the filters are centered and pulled flat is obtained, it is recommended that filters be prepared from without air bubbles. Replace the filters if any irregularities several different aliquots of the dust suspension. For this are seen on the filter surface- Before filtration of each set of scries of filters, it is recommended that the volume of each sample aliquots, prepare a blank filter by filtration of 50 mL aliquot of the original suspension be a factor of five higher of particle-free water. If aliquots of the same sample are than the previous one. If the filters are prepared in order of filtered in order of increasing concentration, the glass filtra increasing aliquot volume, all of the fillets for one sample tion unit need not be washed between filtration. After can be prepared using one plastic disposable filtration unit, completion of the filtration, do not allow the filtration funnel or without cleaning of glass filtration equipment between assembly to dry because contamination is then more difficult individual filtration. Before withdrawal of eadi aliquot from to remove. Wash any residual suspension from the filtration the sample, shake the suspension without additional assembly by holding it under a flow of water, then rub the sonification and allow to rest for 2 min. 10.4.15 There are many practical methods for drying surfam with a clean paper towel soaked in a determent MCE filters. The following are two examples that can be used: solution. Repeat the cleaning operation, and then rinse two (1) dry MCE filters for at least 12 h (over desiccant) in an times in particle-free water. airtight cabinet-type desiccator (7.21); (2) to shorten the 10.4.6 With the flask at atmospheric pressure, add 20 mL drying time (if desired), remove a plug of the damp filter and of particle-free water into the ftinnel. Cover the filter funnel attach it to a glass slide (7.19) as described in 12.1.2 Ahd with its plastic cover if the disposable filtering unit is used, 12.1.3. Place the slide with a filter plug or filter plugs (up to 10-4.7 Briefly hand shake (3 s) the capped bottle with the eight plugs can be attached to one slide) on a bed of sample suspension, then place it in a tabletop ultrasonic bath desiccant, in the desiccator for 1 h. „ (7.12) and sonicate for 3.0 min. Maintain the water level in 10-4.16 PC filters do not require lengthy drying before the sonicator at the same height as the solution in sample preparation, but shall be placed in a desiccator for al least 30 bottle. The ultrasonic bath shall be calibrated as described in min before preparation. 20.5. The ultrasonic bath must he operated at equilibrium 10.5 Prepare TEM specimens from small sections of each temperature. After sonicating, return the sample bottle to the dried filter using the appropriate direct transfer preparation i work Surface of the HEPA hood. Preparation steps 10.4.8 method. through 10.4.14 shall be carried out in this hood. 10.4.8 Shake the suspension lightly by hand for 3 s, then 11. Blanks i let it rest for 2.0 min to allow large particles to settle to the 11.1 Prepare sample blanks that include both a process bottom of the bottle or float to the surface. blank (50 mL of partide-free water) for each sei of samples 10.4.9 Estimate the amount of liquid to be withdrawn to analyzed and one unused fiber from each new box of sample produce an adequate filter preparation. Experience has filtcis (MCE or PC) used in the laboratory. If glass filierine shown that a light staining of the finer surface will yield a units are used, prepare and analyze a process blank each time suitable preparation for analysis. Filter at least 1.0 mL, but [he filtering unit is eleaned. Blanks will be considered no more than half the total volume. If after examination in contanunated, if after analysis, they are shown to contain the TEM. the smalles volume measured (1.0 mL) (7.13) more than S3 asbestos structures per square millimetre, This yields an overloaded sample, then perform additional serial generally corresponds to three or four asbestos structures dilutions of the suspenaon. If it is estimated that less than found in ten grid openings. The source of the contamination 1.0 mL of solution has to be fittoed because of the density of must be found before any further analysis can be performed. the suspensioa, perform a serial dilution. Rqcct samples that were processed along with the contami 10.4.9.1 If se^ dilutions are required, repeat step 10.4.8 nated blanks and prepare new atnples a^ the source of the before the serial dilution portion is taken. Do not re-sonicate contamination is found. the original solution or any serial dilutions. The recom 11.2 Prqpare field blanks which are induded with sample mended procedure fora aerial dilution is to mix 10 mL of the sets in the same manner as the samples, to test for contami sample solution with 90 mL of partide-free water in a clean nation during the sampling, shipping, handling, and prepa sample bottle to obtain a 1:10 serial dilution. FoUow good ration steps of the method. laboratory practices when performing dilutions. , 10.4.10 Insert a new disposable pipette halfway into the 12. TEM Specimen Preparation of Mixed Cellnlose Ester ( J suspension and withdraw a portion. Avoid pipetting (MCE) niters any of the lar^ floating or settled perocles. Uncover the filter Nora 1—Uje of either the acetone or the diamcihylforraaaiide- funnel and dispense the mixture from the pipette into the aeeu'e add method is acceptable. v<afbr in the funnel. 12.1 Aeeiow Fusing Method:
5
CITY_21MC100_002847942
NYC-WTC_000363396
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000389978
Policy language on clean areas, HEPA filtration, and sampling expectations for asbestos work.
10 shared non-person entities · 1 shared topics · similarity 0.980
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000438164
EPA SOP excerpts and references for asbestos validation and inspections.
13 shared non-person entities · 1 shared topics · similarity 0.957
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000435395
Part 763 Subpart text related to asbestos standards and testing definitions.
13 shared non-person entities · 1 shared topics · similarity 0.957
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000434918
Continuation of the asbestos validation SOP text with definitions and scope.
13 shared non-person entities · 1 shared topics · similarity 0.957
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000434667
Environmental protection document detailing Part 763 asbestos definitions and related sections.
13 shared non-person entities · 1 shared topics · similarity 0.957
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000433711
Page from Part 763 asbestos standard; references to testing and enforcement sections.
13 shared non-person entities · 1 shared topics · similarity 0.957
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000451982
Chain-of-custody and SOP excerpt focusing on asbestos validation and PCB spiking.
13 shared non-person entities · 1 shared topics · similarity 0.957
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000445985
Chain-of-custody excerpt referencing Part 763 sections and regulatory definitions.
13 shared non-person entities · 1 shared topics · similarity 0.957
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000318556
Information sheet on asbestos design and analysis standard D5755, undated revision notes.
11 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000219925
Document excerpt of 40 CFR Part 763 Appendix A detailing mandatory and non-mandatory analytical methods for asbestos in schools as of January 2002.
11 shared non-person entities · 1 shared topics · similarity 0.974
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000208957
Document excerpt outlining standard test methods for analyzing asbestos concentrations in dust samples using microscopy techniques.
8 shared non-person entities · similarity 0.967
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000139257
DEP official requests final review of the latest air monitoring Scope of Work to conclude negotiations.
13 shared non-person entities · similarity 0.961
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000125845
Draft fact sheet from DOH and DEP addressing tenant concerns regarding asbestos fibers at 105 Duane Street.
Similarity score 0.992 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000318556
Information sheet on asbestos design and analysis standard D5755, undated revision notes.
Similarity score 0.986 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000208957
Document excerpt outlining standard test methods for analyzing asbestos concentrations in dust samples using microscopy techniques.
Similarity score 0.970 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000125845
Draft fact sheet from DOH and DEP addressing tenant concerns regarding asbestos fibers at 105 Duane Street.
Similarity score 0.952 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000338306
Partial evaluation of asbestos by method 7402 with fiber-concentration guidance.
Similarity score 0.948 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000144624
EPA report detailing microscopy methods for assessing asbestos fiber contamination in carpeting.
Similarity score 0.943 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000318556
Information sheet on asbestos design and analysis standard D5755, undated revision notes.
Similar indexed content
NYC-WTC_000389978
Policy language on clean areas, HEPA filtration, and sampling expectations for asbestos work.
Similar indexed content
NYC-WTC_000219925
Document excerpt of 40 CFR Part 763 Appendix A detailing mandatory and non-mandatory analytical methods for asbestos in schools as of January 2002.
Similar indexed content
NYC-WTC_000208957
Document excerpt outlining standard test methods for analyzing asbestos concentrations in dust samples using microscopy techniques.
Similar indexed content
NYC-WTC_000139257
DEP official requests final review of the latest air monitoring Scope of Work to conclude negotiations.
Similar indexed content