Asbestos by 7402, Health Dept

Machine-extracted title · confidence 25%

Partial evaluation of asbestos by method 7402 with fiber-concentration guidance.

NYC-WTC_000338306–000338313
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

ASBESTOS by TEM: METHOD 7402, Issue 2. dated 15 August 1994 - Page 3 of 7

SAMPLING:

1. Calibrate each personal sampling pump with a representative sampler in line. 2. For personal sampling, fasten sampler to worker's lapel near worker’s mouth. Remove the top cover from cowl extension ("open-face") and orient sampler face down. Wrap joint between extender and monitor body with tape to help hold the cassette together and provide a marking surface to identify the cassette. Where possible, especially at low %RH, attach sampler to electrical ground to reduce electrostatic effects during sampling. 3. Submit at least two field blanks (or 10% of the total samples, whichever is greater) for each set of samples. Remove top covers from the field blank cassettes and store top covers and cassettes in a clean area (e.g., closed bag or box) during sampling. Replace top covers when sampling is completed. 4. Sample at 0.5 to 16 L/min [3]. Adjust sampling rate, Q (L/min), and time, t (min), to produce fiber density, E, of 100 to 1300 fibers/mm [3.85 • 10^ to 5 • 10^ fibers per 25-mm filter with effective collection area (A 385 mm^)] for optimum accuracy. Do not exceed ca. 0.5 mg total dust loading on the filter. These variables are related to the action level (one-half the current standard), L (fibers/cc), of the fibrous aerosol being sampled by:

Ac • E t = ------ =----------, min. Q • L • 10’

NOTE: The purpose of adjusting sampling times is to obtain optimum fiber loading on the filter. A sampling rate of 1 to 4 L/min for 8 h (700 to 2800 L) is appropriate in atmospheres containing ca. 0.1 fiber/cc in the absence of significant amounts of non-asbestos dust. Dusty atmospheres require smaller sample volumes ( <400 L) to obtain countable samples. In such cases take short, consecutive samples and average the results over the total collection time. For documenting episodic exposures, use high rates ( 7 to 16 L/min) over shorter sampling times. In relatively clean atmospheres, where targeted fiber concentrations are much less than 0.1 fiber/cc, use larger sample volumes (3000 to 10000 L) to achieve quantifiable loadings. Take care, however, not to overload the filter with background dust [3]. 5. At the end of sampling, replace top cover and small end caps. 6. Ship samples upright with conductive cowl attached in a rigid container with packing material to prevent jostling or damage. NOTE: Do not use untreated polystyrene foam in the shipping container because electrostatic forces may cause fiber loss from sample filter.

SAMPLE PREPARATION:

7. Remove circular sections from any of three quadrants of each sample and blank filter using a cork borer [4]. The use of three grid preparations reduces the effect of local variations in dust deposit on the filter. 8. Affix the circular filter sections to a clean glass slide with a gummed page reinforcement. Label the slide with a waterproof marking pen. NOTE: Up to eight filter sections may be attached to the same slide. 9. Place the slide in a petri dish which contains several paper filters soaked with 2 to 3 mL acetone. Cover the dish. Wait 2 to 4 min for the sample filter(s) to fuse and clear. NOTE: The "hot block" clearing technique [5] of Method 7400 or the DMF clearing technique [6] may be used instead of steps 8 and 9. 10. Transfer the slide to a rotating stage inside the bell jar of a vacuum evaporator. Evaporate a 1- by 5-mm section of a graphite rod onto the cleared filter(s). Remove the slide to a clean, dry,- covered petri dish [4], 11. Prepare a second petri dish as a Jaffe wick washer with the wicking substrate prepared from filter or lens paper placed on top of a 12-rTim thick disk of clean, spongy polyurethane foam [7].

NIOSH Manual of Analytical Methods (NMAM), Fourth Edition, 8/15/94

CIT Y__2 IMC10 0_0 0 8 9 866 8 4

NYC-WTC_000338309

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000338309Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000447379

PCM asbestos and related fiber analysis methodology overview with sampling details.

Similar indexed content

Compare copies and versions →