NYC 9/11 Public Portal Document
~
I Ckistopher D'Andrea - Cover;sample summar)(3-22.wp^
New York State Department of Labor
Division of Safety and Health
Sampling Summary as of 3/22/02
Personal exposure sampling has been performed on numerous employees working on and
around the WTC site. This has included firefighters, police officers, state troopers, corrections
officers, police detectives, and sanitation workers. The New York State Department of Labor has
to date collected over 350 personal exposure samples on public employees working at the site.
Over 2500 analyses have been obtained on personal, area, bulk, and grab samples. The sampling
summary below is for activity up to 3/12/2002.
Asbestos Over 50 personal samples have been collected so far with results ranging
from not detectable to 0.116 fibers per cc by PCM analysis. The use of TEM on 2
samples which initially were above the PEL of 0.1 fibers per cc resulted in a
reduction to at least 0.016 fibers per cc. Most results by PCM analysis have been
well below the PEL of 0.1 fibers /cc.
Bulk wipe samples were collected in FDNY vehicles during the months of
January and February to assist the department with an evaluation of
contamination. All of these samples had results which were below the
detection limit.
Carbon Monoxide Results for 44 personal exposure samples ranged from 0 to 12 ppm as a
time weighted average, well below the PESH PEL of 35 ppm. Peak measurements
reached 97 ppm on a personal monitor, still well below the ceiling limit of 200 ppm.
Silica Personal sampling results have shown most exposures to be below the
detection limit for respirable silica with all exposures well below the
PESH PEL of 0.1 mg/m3
Metals Personal samples (42) collected show all exposures to be below the PESH
PELS. Metals analyzed included lead, copper, manganese, molybdenum,
magnesium, cadmium, nickel, iron, aluminum, zinc, and cobalt.
Surface wipe samples in some of the FDNY’s response vehicles were
taken to assist the department with an evaluation of contamination of
vehicles which had responded to the WTC site during the first few days of
the disaster. These results are included in the data spreadsheet.
Volatile organics All personal sampling results have been well below PESH limits for 32
samples collected for volatile organics. These samples included analyses for the
following: acetone, benzene, ethyl benzene, butyl alcohol, isopropyl alcohol, naphtha,
styrene, toluene, and xylene.