NYC 9/11 Public Portal Document
I Christopher D'Andrea- Coyer-sample summa^ ^ .. Page 2 I
Acid gases Exposures to acid gases such as hydrogen bromide, hydrogen chloride,
hydrogen cyanide, and hydrogen fluoride were all below the detection limit. For
sulfuric acid, the highest exposure found was in mid October and was at a level of
0.48 mg/m3, less than half of the limit of 1 mg/m3
PCBs The two personal exposure samples for PCBs on workers monitoring the
debris pile had results which were less than the detection limits.
Mercury All 43 personal air samples for mercury have had results which were less
than the detection limit. Out of 22 wipe samples for mercury on FDNY vehicles,
21 were below the detection limit and the only positive result was a trace amount
of 0.37 ug/100 cm2
Noise Personal monitoring for noise exposure on public employees did not reveal
any exposures above the action level 85 dBA. The highest exposure
recorded was 83.6 dBA as an 8 hour time weighted average.
Total dust Of 53 personal samples were collected for total dust, only two were above
the PEL of 15 mg/m3. These two samples were taken on workers actively looking
through the debris and they were wearing respirators.
Respirable dust There have been 34 personal samples for respirable dust collected . None
of the samples have approached the PEL of 5 m^m3.
CITY_21MC100_008971408