4.1 Siting Considerations
The siting criteria for wash/decontamination stations listed below should be followed to
enhance protection of personnel within work areas and the general public, and to prevent
spreading dust outside the work areas:
• Locate along designated routes to disposal site(s) and in close proximity to work
areas.
• Avoid locating in public traffic areas and pedestrian zones. If this is not possible,
construct barriers to keep out unauthorized personnel.
• Keep away from overhead utilities.
• Select a site with sufficient space to construct a contained wash area with an adjacent
area for stockpiling saturated sediment/debris.
• Locate near a clean water source (e.g., fire hydrant) or where a tank can be placed.
• Locate near an acceptable wash water disposal receptor (e.g., sanitary sewer not a
storm water drain or outfall).
4.2 Activities
To prevent/minimize the spread of dust outside work areas, the following activities
should be performed at wash areas:
• Wash the truck’s sides, tailgate, tires, and undercarriage.
• Verity haul truck loads are wet down or covered and the cover is securely attached.
Haul trucks should not be allowed to leave wash/decontamination stations unless
these measures have been completed.
• Properly manage wash water and sediment/debris resulting from wash area activities.
4.3 Operation and Maintenance of Decontamination Wash Stations
If prescribed “action levels” are exceeded, decontamination wash stations should be
operated and maintained to ensure haul trucks are affectively decontaminated and
resulting wash water and sediment/debris contained. The following measures are
provided as examples of options available for managing contained wash water and
sediment/debris:
• If possible, pump accumulated wash water from wash containment area into a settling
tank(s) with baffle(s) to promote separation of oils, sediment/debris, and water.
- As needed for reuse or discharge, pump water from discharge side of settling tank
through a five (5) micron, in-line, filter.
- If possible, use electric pumps.
- If generators or gas pumps are used, they should be placed in secondary
containment with oil absorbent material and fire extinguisher readily available.
- Removal of sediment from tank can be accomplished with the use of sludge
vacuum (e.g., vacuum truck).