NYC 9/11 Public Portal Document
DUST PROTECTION AND SUPPRESSION PLAN
• If a settling tank is not used, accumulated wash water should be pumped through a
non-woven filter bag that is place in a contained area adjacent to the
wash/decontamination station.
- Filtered water should then be checked for hydrocarbon contamination (e.g., sheen
or odor). If fuel/oil contamination is identified, oil absorbent material/boom should
be used to remove contamination and these materials disposed of properly.
- As needed for reuse or discharge, pump water through a five (5) micron, in-line,
filter.
• If wash water is not filtered, it should only be discharged into a sanitary sewer or
water tankers for transport to an approved disposal site.
• If possible, debris/sediment from wash/decontamination station should be stockpiled
in an adjacent contained area to allow saturated sediment/debris to drain prior to
being loaded into haul trucks and transported to disposal site(s). If draining of
saturated sediment/debris is not possible, trucks transporting saturated material should
have dump bed liners to contain liquids during transport to disposal site(s).
4.4 Personal Protective Measures
Personnel involved in wash/decontamination station activities will be responsible for
removing accumulated dust from vehicles leaving the work area and ensuring loads are
properly wet down or covered. Consequently, they will be exposed to dust, wet conditions,
and debris/sediments and should use the following measures to help protect themselves
against possible hazards:
• Head covering
• Approved dust mask
• Face shield
• Rubber gloves
• Water repellent outer clothing
• Rubber boots
When returning home, wash/decontamination station workers should follow the recommended
protection measures described above in Section 2.3, Returning Home.
9/19/2001 Page 5 of 5 DRAFT
CITY_21MC100_000948297
NYC-WTC_000317886
OCR can misread numbers and units. Confirm readings against the page image before using them.