that the Tier I level of .028 f7cc PCM equivalents roughly equates to the AHERA TEM standard
of 70 f'nun^ (.022 fZcc) in total fiber counts. Based on empirical information from the WTC
ambient air monitoring program [EPA, 2002c] that recorded less than 20% of total AHERA
TEM fiber counts to be >5 um in length, the AHERA TEM standard of 70 fmm^ (.022 f/cc) and
the alternate AHERA PCM standard of .01 fee both meet the risk-based criteria established for
the Tier I screening level.
The Tier I level for asbestos in settled dust was based on K factors [Millette and Hays, 1994]
which are empirical relationships between concentrations of asbestos fibers in settled dust and
indoor air. Millette developed the K factors by studying matched air and settled dust samples
taken fi-om various homes, at varying levels of activity in the home. The Tier I level was based
on the K factor for a worst case scenario of a high level of activity. Although K factors are not
rigorous enough to rely upon for a firm health decision, they are used here only to define what
might constitute elevated fiber counts, that would need to be addressed as a near-term concern.
This approach may overestimate potential exposures, but as such, is protective.
15
CITY_21MC100_008969687
NYC-WTC_000317670
OCR can misread numbers and units. Confirm readings against the page image before using them.
NYC-WTC_000317670Source: NYC Law Department, mirrored locally