NYC 9/11 Public Portal Document
Asbestos
Tier Action Asbestos (Settled Dust) Asbestos (indoor air)
Level Basis Level Basis
I Aggressive > 30,000 Millette’s K factor >0.028 f/cc * 0.028 f/cc
cleaning. If levels f/cm’ to estimate represents a 1X10
persist, take airborne levels for risk estimate for a
additional action to different activities 1 year exposure
reduce exposure. (see narrative
below).
Evaluate
conditions in the
area, including
representativeness
of air samples,
asbestos settled
dust levels, and
loading.
II Maintain 30,000 0.028 f/cc 0.0009 f/cc
recommended f/cm^ to 0.0009 f/cc represents a 1X10’’
cleaning methods. background (or risk estimate for a
Consider additional background) 30 year exposure
monitoring.
Evaluate
conditions in the
area including
representativeness
of air samples,
fibrous glass
settled dust levels
and loading.
ni No further action Background Level is set at that 0.' 9 f/cc Level is set at that
required. found in (or found in
background, or background) background, or
unaffected, areas, unaffected, areas.
so that no increase In this way, no
in risk due to the increase in risk due
asbestos fibers to the asbestos
would be fibers would be
expected. expected.
* f/cc = fibers (greater than 5 micrometers long) per cubic centimeter of air.
Air concentrations measured by PCM, NIOSH 7402, confirmed by TEM. It should be noted