NYC 9/11 Public Portal Document
Dioxin
Tier Action Dioxin (settled dust) Dioxin (indoor air)
Level Basis Level Basis
I Aggressive >70 ng/m^ 70 ng/m^ >0.03 ng/m’ 0.03 ng/m’
cleaning. If levels represents a represents a
persist, take 1X10^ risk 1X10-“ risk
additional action to estimate for a 1 estimate for a 1
reduce exposure. year exposure year exposure
II Maintain 70 ng/m^ to 2 2 ng/m’ 0.03 ng/m’ to 0.001 ng/m^
recommended ng/m^ (or represents a 0.001 ng/m’ (or represents a
cleaning methods. background) 1X10-“ risk background) 1X10-“ risk
Consider additional estimate for a 30 estimate for a
monitoring year exposure 30 year
exposure
III No further action <2 ng/m’ (or Level could also <0.001 ng/m’ Level could
background) be set at that (or background) also be set at
found in that found in
background, or background, or
unaffected, areas, unaffected,
so that no areas, so that
increase in risk no increase in
due to dioxin risk due to
would be dioxin would
expected. be expected.
The table above reflects the proposed cancer Slope Factor for 2,3,7,8 TCDD and the toxicity
equivalence paradigm for carcinogenic dioxin/furan congeners present in EPA’s draft dioxin
reassessment [EPA, 2001]. An equivalent table reflecting the current IRIS verified cancer Slope
Factor for 2,3,7,8 TCDD would be represented by multiplying all listed values by a factor of 6.
The inputs to the dose equations were adopted from the exposure assumptions that NYSDOH
used in assessing office buildings in Binghamton, NY, and the proposed cancer slope factor for
dioxin. In addition, the Tier I and III benchmarks equate to a lifetime exposure level which is
approximately 1/10 of that which results from current dietary intake of dioxin (65 pg/d). It is
thus reasonable to assume that any lower level of exposure would result in an inconsequential
reduction in the current risk levels experienced by the general U.S. population.
NYC background would also be an important consideration in determining the appropriate
longer-term value. Propose selecting the longer-term value on the basis of a 1 E-04 risk level or
NYC background.
13
CITY_21MC100_008969685
NYC-WTC_000317668
OCR can misread numbers and units. Confirm readings against the page image before using them.