NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 50 pages

COPC World Trade Center Report, 50 pages

Machine-extracted title · confidence 50%

COPC committee report on World Trade Center contaminants with multi-agency authors.

NYC-WTC_000348649–000348698
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Table 6. Dioxin

Tier Action Dioxin (settled dust) Dioxin (indoor air) Level Basis Level Basis

I Aggressive >120 rig/m"' 120 ng/m’ >0.03 ng/m’ 0.03 ng/m’ cleaning. If levels represents a represents a persist, take 1x10'' risk 1x10"* risk additional action to estimate for a 1 estimate for a 1 reduce exposure. year exposure year exposure n Maintain 120 ng/m^ to 4 ng/m’ 0.03 ng/m’ to 0.001 ng/m’ recommended 4 ng/m’ (or represents a 0.001 ng/m’ (or represents a cleaning methods. background) IxlO"* risk background) 1x10^ risk Consider additional estimate for a 30 estimate for a monitoring year exposure 30 year exposure in No further action <4 ng/m^ (or Level could also <0.001 ng/m’ Level could background) be set at that (or background) also be set at found in that found in background, or background, or unaffected, areas, unaffected, so that no areas, so that increase in risk no increase in due to dioxin risk due to would be dioxin would expected. be expected.

Toxicity criteria for dioxin:

Oral Slope Factor = 1.0 E 06 (mg/kg/day) ‘ [EPA, 2001]

(Inhalation cancer risk was calculated by route-to- route extrapolation of oral Slope Factor)

The table above reflects the proposed cancer Slope Factor for 2,3,7,8 TCDD and the toxicity equivalence (TEQ) paradigm for carcinogenic dioxin/furan congeners present in EPA’s draft dioxin reassessment [EPA, 2001]. An equivalent table reflecting the previous IRIS-verified cancer Slope Factor for 2,3,7,8 TCDD would be represented by multiplying all listed values by a factor of six.

The methodology for estimating dose from wipe sampling data (see Appendix D) is consistent with the approach NYSDOH used in assessing office buildings in Binghamton, with modifications made to input parameters to reflect residential rather than occupational exposure. In addition, the Tier HI benchmark equates to a lifetime exposure level which is approximately

19

CITY_21MC100_003012109

NYC-WTC_000348667

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000348667Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000348699

COPC committee report with contributors from EPA, NYC DEP, and state agencies.

Similar indexed content

Compare copies and versions →