NYC 9/11 Public Portal Document

Table 6. Dioxin

Tier Action Dioxin (settled dust) Dioxin (indoor air) Level Basis Level Basis I Aggressive cleaning. >120 ng/m^ 120 ng/nr >0.03 ng/m^ 0.03 ng/m' If levels persist, take represents a 1x10’ represents a additional action to risk estimate for 1x10"* risk reduce exposure. a 1 year exposure estimate for a 1 year exposure II Maintain 120 ng/m^ to 4 ng/m^ 0.03 ng/m’ to 0.001 ng/m recommended 4 ng/m^ (or represents a 1x10' 0.001 ng/m^ (or represents a cleaning methods. background) '* risk estimate for background) 1x10-* risk Consider additional a 30 year estimate for a monitoring exposure 30 year exposure III No further action <4 ng/m^ (or Level could also <0.001 ng/m’ (or Level could background) be set at that background) also be set at found in that found in background, or background, or unaffected, areas, unaffected, so that no areas, so that no increase in risk increase in risk due to dioxin due to dioxin would be would be expected. expected.

Toxicity criteria for dioxin;

Oral Slope Factor = 1.0 E 06 (mg/kg/day)'' [EPA, 2001]

(Inhalation cancer risk was calculated by route-to- route extrapolation of oral Slope Factor)

The table above reflects the proposed cancer Slope Factor for 2,3,7,8 TCDD and the toxicity equivalence (TEQ) paradigm for carcinogenic dioxin/furan congeners present in EPA’s draft dioxin reassessment [EPA, 2001]. An equivalent table reflecting the previous IRIS-verified cancer Slope Factor for 2,3,7,8 TCDD would be represented by multiplying all listed values by a factor of six.

The methodology for estimating dose from wipe sampling data (see Appendix D) is consistent with the approach NYSDOH used in assessing office buildings in Binghamton, with modifications made to input parameters to reflect residential rather than occupational exposure. In addition, the Tier III benchmark equates to a lifetime exposure level which is approximately one tenth of that which results from current dietary intake of dioxin (65 pg/d). It is thus reasonable to assume that any lower level of exposure would result in an inconsequential reduction in the current risk levels experienced by the general U.S. population.

Information regarding NYC background levels also would be an important consideration in

17

CITY_21MC100_003012317

NYC-WTC_000348715

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000348715Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000348649

COPC committee report on World Trade Center contaminants with multi-agency authors.

Similar indexed content

Compare copies and versions →