NYC 9/11 Public Portal Document
It should be noted that the Tier I level of 0.028 f/cc PCM equivalents roughly equates to the
AHERA TEM standard of 70 f/mm^ (0.022 f/cc) in total fiber counts. Based on empirical
information from the WTC ambient air monitoring program [EPA, 2002c] that recorded less than
20% of total AHERA TEM fiber counts to be >5 um in length, the AHERA TEM standard of 70
f/mm^ (0.022 f/cc) and the alternate AHERA PCM standard of 0.01 f/cc both meet the risk
based criteria established for the Tier I screening level.
The Tier I level for asbestos in settled dust was based on K factors [Millette and Hays, 1994],
which are empirical relationships between concentrations of asbestos fibers in settled dust and
indoor air. Millette developed the K factors by studying matched air and settled dust samples
taken from various homes, at varying levels of activity in the home. The Tier I level was based
on the K factor for a worst case scenario of a high level of activity. Although K factors are not
rigorous enough to rely upon for a firm health decision, they are used here only to define what
might constitute elevated fiber counts, that would need to be addressed as a near-term concern.
This approach may overestimate potential exposures, but as such, is protective.