NYC-WTC_000383864
ATC report of IAQ measurements collected at P.S. 89M for BOE evaluation.
15 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗March 19, 2002 IAQ report for PS 89M site visit.
NYC-WTC_000313356–000313360OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Mr. Bernard P. OrIan March 19, 2002 Indoor Air Quality Assessment Page 4 P. S. 89M ATC Project No. 15-19125-0297 average PM2 5 concentration for the entire school building was approximately 14 pg/m^. All of the seventy (70) instantaneous indoor readings were below the USEPA recommended concentration of 40 pg/m^ for sensitive individuals and children. The outdoor respirable particulate concentration measurements ranged from 19 to 23 pg/m^ with an average of 21 pg/m3. All outdoor measurements were below the NPAAQS of 65 pg/m^ 24-hour average concentration of particulate matter 2..5 micrometers or less in aerodynamic diameter and the EPA recommended guideline for children and sensitive individuals of 40 pg/m3-
* The measurements made during this assessment were instantaneous readings, the NP,AAQS is a 24-hour average.
TVOC Concentrations
TVOCs were not detected anywhere inside the building (0.0 ppm). The outdoor TVOC concentration was also 0.0 ppm.
OBSERVATIONS
During this assessment, ATC noted the following: • The school building was occupied at the time of the assessment. • No smoke odor was detected m the building • The interior of the building appeared clean and free of dust and debris.
FINDINGS
Based on the real-time measurements, the following findings are presented;
1. Concentrations of respirable particulates, CO and T VOCs were below applicable standards and guidelines. 2. Sixteen (16) of the indoor measurements for temperature were below and fifty-four (54) were within the range of 68 to 75°F (at 50 percent relative humidity) as recommended by the ASHRAE Standard 55-1992 during the heating season (wintertime conditions). 3. Forty-six (46) of the indoor measurements for relative humidity were below and twenty-four (24) were within the ASHRAE-recommended range of 30 to 60 percent for occupant comfort. 4. Four (4) of the CO2 indoor measurements were above the ASITRAE Standard 62-1999 recommended maximum concentration of <700 ppm above the background level. The two (2) highest readings (1213 ppm) were measured in room 404 with 28 occupants at 10:30 AM and in room 526 with 209 occupants at 11:30 AM. Levels above the recommended maximum do not indicate a health risk. Carbon dioxide measurements are used as an indicator of available outside makeup air. The primary' source of CO2 indoors is occupant respiration.
CITY_21MC100_0 03047482
NYC-WTC_000313359
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000383864
ATC report of IAQ measurements collected at P.S. 89M for BOE evaluation.
15 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000313369
IAQ assessment update for PS 89M dated March 18, 2002.
15 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000400243
IAQ measurements at PS 89M for BOE evaluation, March 2002.
15 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000369723
ATC IAQ measurements at PS 89M for BOE, May 2002.
14 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000397271
IAQ measurements report for PS 234M, Apr 2002.
12 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000199187
Letter from ATC Associates reporting indoor air quality measurements collected at P.S. 234M on April 11, 2002.
12 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000220651
Formal indoor air quality assessment report submitted to the Board of Education regarding measurements taken at PS 89M on April 17, 2002.
14 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000394408
Report of IAQ measurements at P.S. 89M in April 2002, per BOE request.
14 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000313339
ATC IAQ memo detailing measurements and scope of work at PS 89M.
15 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000199010
Cover letter from ATC Associates submitting indoor air quality measurement results for PS89M collected on May 8, 2002.
14 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000313487
ATC IAQ measurements at PS 89M for BOE air quality evaluation.
14 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000392778
ATC indoor air quality measurements collected May 3, 2002 for BOE.
14 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000400243
IAQ measurements at PS 89M for BOE evaluation, March 2002.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000313369
IAQ assessment update for PS 89M dated March 18, 2002.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000199187
Letter from ATC Associates reporting indoor air quality measurements collected at P.S. 234M on April 11, 2002.
Similarity score 0.995 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000397271
IAQ measurements report for PS 234M, Apr 2002.
Similarity score 0.994 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000383864
ATC report of IAQ measurements collected at P.S. 89M for BOE evaluation.
Similarity score 0.993 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000220651
Formal indoor air quality assessment report submitted to the Board of Education regarding measurements taken at PS 89M on April 17, 2002.
Similarity score 0.992 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000383864
ATC report of IAQ measurements collected at P.S. 89M for BOE evaluation.
Similar indexed content
NYC-WTC_000313369
IAQ assessment update for PS 89M dated March 18, 2002.
Similar indexed content
NYC-WTC_000400243
IAQ measurements at PS 89M for BOE evaluation, March 2002.
Similar indexed content
NYC-WTC_000369723
ATC IAQ measurements at PS 89M for BOE, May 2002.
Similar indexed content
NYC-WTC_000397271
IAQ measurements report for PS 234M, Apr 2002.
Similar indexed content