NYC-WTC_000271280
Memo reporting indoor air quality assessment at Stuyvesant High School, Nov 2001.
14 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗Nov 6, 2001 memo regarding IAQ assessment at Stuyvesant High School for BOE.
NYC-WTC_000311960–000311964OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Mr. Bernard P. Orlan November 6. 2001 Indoor Air Quality Assessment Page 3 Stuwesant Hish School (M477) ATC Project No. 15-19125-0246
Real-Time Environmental Measurements
ATC collected one hundred and eighteen (118) sets of real-time environmental measurements consisting of one hundred and fifteen (116) in the school building and two (2) outdoors. All ten floors of the school were sun-eyed. These results are described below. Field data sheets are found in Attachment 1. Readings began at 8:20 A.M. and concluded after 1:15 P.M.
Temperature
Indoor dry bulb temperature measurements ranged from 69.6 °F to 77.2 °F. Twenty-seven (27) measurements were above the range of 68 to 75 °F (at 50 percent relative humidity) recommended by ASHRAF Standard 55-1992 during the heating season (wintertime conditions). These measurements were collected in rooms on the 6^^, 5^^, 4^^, 3rd 2“^^ floors. The outdoor temperature range was 52.1 to 54.4 °F.
Relative Humidity
The relative humidity indoors ranged from 20.0 percent to 34.1 percent. Only five (5) measurements were within the ASHRAE-recommended range of 30 to 60 percent for occupant comfort. The outdoor relative humidity measurements were 24.4 and 29.4 percent.
Carbon Dioxide Concentratim
Carbon dioxide concentrations indoors ranged from 401 ppm to 1583 ppm. Thirteen (13) CO2 measurements were above the ASHRAF Standai’d 62-1999 recommended maximum concentration of <700 ppm above the background level. The outdoor (backgroimd) CO2 concentrations were 377 and 373 ppm. Therefore, the maximum acceptable level of CO2 at this location was 1077 ppm (background level + 700 ppm). The highest reading, 1583 ppm, was in Room 525. Rooms with CO2 levels above the recommended maximum were found on the 3’^’^, 4th, 5th and 6^^ floors. Levels above the recommended maximum do not indicate a health risk. Carbon dioxide measurements are used as an indicator of available outdoor air. The primary source of CO2 indoors is occupant respiration.
Carbon Monoxide Concentration
Carbon monoxide was not detected anywhere inside the building (0 ppm). The outdoor CO concentration was also 0 ppm.
Respirable Particulates (PA/2,s)
Respirable particulate concentrations indoors ranged between 5 pg/m^ and 21 pg/m^. All of the measurements were below the NP.AXQS of 65 pg/m^ 24-hour average concentration of particulate matter 2.5 micrometers or less in aerodynamic diameter. The outdoor respirable particulate concentrations were 27 and 36 pg/m^.
CITY_21MC1OO_OO3O45816
NYC-WTC_000311962
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000271280
Memo reporting indoor air quality assessment at Stuyvesant High School, Nov 2001.
14 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000311846
ATC letter enclosing IAQ assessment results for Stuyvesant HS.
13 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000182709
Cover letter from ATC Associates submitting an indoor air quality assessment report for Stuyvesant High School conducted on November 9, 2001.
14 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293077
Indoor air quality assessment conducted at Stuyvesant High School on Nov 2, 2001 for NYC Board of Education.
14 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000188540
Report detailing an indoor air quality assessment conducted at a school on Chambers Street on October 25, 2001.
14 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000182684
Cover letter from ATC Associates submitting an indoor air quality assessment report for Stuyvesant High School conducted on November 1, 2001.
14 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000312017
Nov 9, 2001 memo regarding IAQ assessment at Stuyvesant High School.
14 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000311922
ATC release of indoor air quality assessment results for Stuyvesant HS.
13 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000271198
Indoor air quality assessment report for Stuyvesant High School.
14 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000182689
Cover letter from ATC Associates submitting an indoor air quality assessment report for Stuyvesant High School conducted on November 2, 2001.
14 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000197564
Letter from ATC Associates reporting an indoor air quality assessment conducted at a Board of Education school in November 2001.
14 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000182704
Cover letter from ATC Associates submitting an indoor air quality assessment report for Stuyvesant High School conducted on November 8, 2001.
14 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000311846
ATC letter enclosing IAQ assessment results for Stuyvesant HS.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000197534
Letter from ATC Associates reporting an indoor air quality assessment conducted at a Board of Education school in October 2001.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000312017
Nov 9, 2001 memo regarding IAQ assessment at Stuyvesant High School.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000312245
Ltr: indoor air quality measurements at Stuyvesant High School.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000311313
ATC report of IAQ measurements at Stuyvesant High School (M477).
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000271280
Memo reporting indoor air quality assessment at Stuyvesant High School, Nov 2001.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
Memo reporting indoor air quality assessment at Stuyvesant High School, Nov 2001.
Similar indexed content
NYC-WTC_000311846
ATC letter enclosing IAQ assessment results for Stuyvesant HS.
Similar indexed content
NYC-WTC_000182709
Cover letter from ATC Associates submitting an indoor air quality assessment report for Stuyvesant High School conducted on November 9, 2001.
Similar indexed content
NYC-WTC_000293077
Indoor air quality assessment conducted at Stuyvesant High School on Nov 2, 2001 for NYC Board of Education.
Similar indexed content
NYC-WTC_000188540
Report detailing an indoor air quality assessment conducted at a school on Chambers Street on October 25, 2001.
Similar indexed content