Mr. Bernard P. Orlan April 15, 2002 Respirable Particulate Monitoring Page 2 Various Locations/Manhattan ATC Project No. 15-19125-0314

TARGET GUIDELINES FOR AIR QUALITY PARAMETERS EVALUATED*

Respirable 65 micrograms per cubic Particulates meter of air (gg/m^) 24 USEPA NPAAQS (PM2.5) hour average Respirable USEPA recommendation Particulates 40 ^g/m3 24 hour average for children/sensitive (PM2.5) individuals USEPA = United States Environmental Protection Agency NPAAQS = National Primary Ambient-Air Quality Standard

REAL-TIME SAMPLING RESULTS

Twenty-nine (29) outdoor and twenty-eight (28) indoor respirable particulates measurements* were collected from approximately twenty-eight school locations in Manhattan, ranging from West 11* Street to East 25*’’ Street. The measurements were made from 5:45 A.M. to 4:15 P.M. The lAQ field report forms are provided as the Attachment.

The outdoor PM2.5 concentrations ranged from 34 gg/m^ to 51 gg/m3 with an average of 39 gg/m^. The indoor concentrations ranged from 25 gg/m^ to 35 gg/m3 with an average of 31 gg/m^. None of the indoor measurements were above the NPAAQS of 65 gg/m^ 24-hour average concentration of particulate matter 2.5 micrometers or less in aerodynamic diameter and the USEPA recommended concentration of 40 gg/m^ for sensitive individuals and children. Eleven (11) of the outdoor instantaneous measurements were above the EPA recommended concentration of 40 gg/m^ for sensitive individuals and children. * These measurements were instantaneous readings, the NPAAQS and the recommendation for children are 24-hour averages.

CONCLUSION

Based on our measurements, none of the indoor measurements were above the NPAAQS of 65 jxg/m^ 24-hour average concentration of particulate matter 2.5 micrometers or less in aerodynamic diameter and the USEPA recommended concentration of 40 gg/m^ for sensitive individuals and children. Eleven (11) of the outdoor instantaneous measurements were above the EPA recommended concentration of 40 gg/m^ for sensitive individuals and children.

CITY_21MC100_0 03044031

NYC-WTC_000310335

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000310335Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →