Bulk sample analysis report, GPS 222 Broadway, 2002

Machine-extracted title · confidence 50%

Bulk sample analysis for multiple samples at 222 Broadway building; project IDs and sample IDs listed.

NYC-WTC_000306462–000306463
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

UN-17-2002 02;00P FROM: TO:1£12S360041 P:2^14

KAM CONSULTANTS 35-41136th Street Long Island City

J(ani New York, 11106 Tel: (718)729-199? Fax:(718)729-1876

BULK SAMPLE ANALYSIS REPORT CLIENT: GPS Environmental Consultants, Inc., 31 Trescott Path, Fort Salonga, New York, 11768 BUILDING ADDRESS: 222 Broadway, Manhattan - 29th,24th,23rd,22nd,20th,18th,16thJ5th Floors PROJECT#: Client Sample ID/#: 01-29 02-29 03-24 04-23 05-22 Lab Sample ID#: 020514A-1278 020514A-1279 020S14A-I280 0205 t4A-l 281 020514A-1282 Sample Location: 29th Floor Cooling 29th Floor Cooling 24th Floor Center 23ril Floor S/West 22nd Floor West Tower N/East Tower S/East on Set Back Comer Set Back Comer Set Back Comer Flashing Comer Flashing Roof Flashing Roof Flashing Roof Flashing

Homogeneity: Yes Yes Yes Yes Yes Sample Description: Wipe Wipe Wipe Wipe Wipe

Color: Wh/Bm Wh Wh Wh/Gr Gr/Wh

Texture: Mixed Mixed Mixed Mixed Mixed Sample Treatment: None None None None None

Asbestos Present: (Type & Percent) ND ND ND ND ND Total Percent Asbestos: 0% 0% 0% 0% 0% Other Fibr, Mat. (Type & Percent): <1%FBGL <1%SYNTH t%SYNTH 1%CELL <1%CELL 5%SYNTH Non Fibr. Mat. (Percent): 94% >99% 99% 99% >99% Date Received: 5/14/02 Date of Analysis; 5/14/02 Date of Report: 5/15/02

Analyst: Lab Manager!: Row Louis David Chen * Analysis of samples is performed JWy Polarized Light Microscopy (PLM) - Point Counting Method (EPA 600/M4-82-020) * Analytical equipments; Stereobinocular microscope (MEIJI EMT-Serial # 25930), Polarized Light Microscope (MEIJI ML-POL-Serial # 88034) * PLM is not consistently reliable in detecting asbestos in floor coverings and similar non-friable organically bound materials. Quantitative transmission electron microscopy is currently the only method that can be used to determine if this material can be considered or treated as non-asbestos-containing * Samples will be stored for ninety (90) days and then returned to the client upon request * The results relate only to the items calibrated or tested. * The certificate of report shall not be reproduced without the written approval of the laboratory. * The report must not be used by the client to claim endorsement by NVLAP or any agency of the US Government, IWS-DOH ELAP #11273 yiST-NVLAP# 102047 AIHA#; 100269

Page 1 of 2

CITY_DEP_WORBY_CANNATA_SUBP_000007207

NYC-WTC_000306462

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000306462Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →