TEM analysis, NSHA-EB&R-10/8-04, Oct 2001

Machine-extracted title · confidence 43%

TEM analysis data for NSHA-EB&R-10/8-04, exterior site, 10/08/01.

NYC-WTC_000293403
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

ATC Environmental, Inc. 104 East 25th Street New York, New York 10010

N.Y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date: 10/08/01

ASBESTOS FIBER TkNALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS) Method: AHERA Fxnal Rule, EPA Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 30, 1987

gampie Identification Analysis Parameters

Project/Site: New Stuyvesant H.S., 345 Chambers St., NY, NY TEM Sample No.: 5639 60569 Exterior of Building & Roof Date Received: 10/08/01 Grid Openings Analyzed;__ 4

Project Sample No.: NSHA-SB&R-10/8 - 04 Average Grid Opening: 105.00 um

Air Volume: 1881 liters Total Area Analyzed :0^£45£rniTi2

Filter Type; MCE 25 mm diam., Pore Size: 0.45 um Analytical Sensitivity: 22..2.s/mm2 Effective Area: 385 mm2 Q.QQ46 s/cG

F'lBRQUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single Matrix Total. Struct. Filter Air Fibers Bundles Clusters Struct. Struct > = 5um Struct/mm2 Struct/cc ngm/m3

Chrysotile Asbestos 0 0 0 0 0 0 C. 0 0.0000 0

Amphibole Asbestos 0 0 0 0 C 0 c.o 0.0000 0

Ambiguous 0 0 0 0 0 0 0.0 0,0000 0

Total asbestos (includes ambiguous structures) 0 0 0.0 0.0000 0 Non-Asbestos 0 0 0 0 0 0 0.0 0.0000 N/A No Identification 0 0 0 0 0 0 0.0 0.0000 N/A

Totals (All Structures) 0 0 0.0 0.0000 N/A Tile estimated uncertainty of this analysis is 1 standard deviation.

Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type: None detected

The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.

Analyzed by. Report Reviewed by:

Marek Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy

CITY_21MC100_003082042

NYC-WTC_000293403

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000293403Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000294008

TEM analysis of air samples at New Stuyvesant H.S., Oct 2001.

Similar indexed content

NYC-WTC_000293781

TEM analysis for New Stuyvesant H.S. exterior & interior; received 10/21/01.

Similar indexed content

NYC-WTC_000270873

TEM asbestos analysis with AHERA/ERA methods; sample 4 for New Stuyvesant HS.

Similar indexed content

Compare copies and versions →