NYC-WTC_000294008
TEM analysis of air samples at New Stuyvesant H.S., Oct 2001.
8 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗TEM asbestos analysis with SAED/EDS for New Stuyvesant High School, received 10/28/01.
NYC-WTC_000270979OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
ATC Environmental, Inc. 104 East 25th Street New York, New York 10010
N.Y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date: 10/29/01
ASBESTOS FIBER TkNALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS) Method: AHERA Final Rule, EPA Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 30, 1987
Sample Identification Analysis Parameters
Project/Site: New Stuyvesant H.S., 345 Chambers St., NY, NY TEM Sample No.: 5785 - 62429 Exterior & Interior of Building & Roof Date Received-: 10/28/01 Grid Openings Analyzed:__ 4
Project Sample No.: 20 Average Grid Opening: 106.00 um
Air Volume: 1944 liters Total Area Analyzed: 0.04SO mm2
Filter Type: MCE 25 mm diam., Pore Size: 0.45, um Analytical Sensitivity;22^2 s/mrn2 Effective Area: 385 mm2 0,0044 S/CC
FIBROUS PARTICULATES ANALYZED Nunxber Observed CONCENTRATION Total ■Single Matrix Total. Struct. Filter Air Fibers Bundles Clusters Struct, Struct >c5um Struct/min2 Struct/cc nam/m3
Chrysotile Asbestos 0 0 0 0 0 0 0.0 0.0000 0
Amphibole Asbestos 0 0 0 0 0 0 0.0 C . 0000 0
Ambiguous 0 0 0 0 0 0 0.0 0.0000 0
Total asbestos (includes ambiguous structures) 0 0 0.0 0.0.000 0 Non-Asbestos 0 0 0 0 0 0 0.0 0.0000 N/A No Identification 0 0 0 0 0 0 0.0 0.0000 N/A
Totals (All Structures) 0 0 0.0 0.0000 N/A The estimated uncertainty of this analysis is 1 standard deviation.
Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type:_None detected
The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.
Analyzed by: Report Reviewed by:
Marek Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy
CITY_21MC1OO_OO3O99948
NYC-WTC_000270979
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000294008
TEM analysis of air samples at New Stuyvesant H.S., Oct 2001.
8 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293900
TEM analysis with structure ID and EDS; exterior/interior building data.
8 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000188696
Laboratory report presenting transmission electron microscopy results for asbestos fibers collected during an inspection of a high school.
7 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000188694
Document containing transmission electron microscopy data for asbestos fiber identification in air samples from a high school building.
7 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293494
TEM data including air volume and EDS for NSHS samples.
8 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293781
TEM analysis for New Stuyvesant H.S. exterior & interior; received 10/21/01.
8 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270871
TEM asbestos analysis for exterior & interior of building at New Stuyvesant HS.
7 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270873
TEM asbestos analysis with AHERA/ERA methods; sample 4 for New Stuyvesant HS.
7 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000182602
Technical data sheet recording air volume and microscopic analysis parameters for exterior and interior samples at Stuyvesant High School.
7 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293970
TEM analysis; New Stuyvesant HS project; received 10/26/01.
8 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270973
TEM asbestos analysis with SAED/EDS for New Stuyvesant HS exterior/interior, Oct 2001.
7 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270858
TEM asbestos analysis with SAED/EDS for New Stuyvesant High School, Oct 2001.
8 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000294008
TEM analysis of air samples at New Stuyvesant H.S., Oct 2001.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293900
TEM analysis with structure ID and EDS; exterior/interior building data.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000188696
Laboratory report presenting transmission electron microscopy results for asbestos fibers collected during an inspection of a high school.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000188694
Document containing transmission electron microscopy data for asbestos fiber identification in air samples from a high school building.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293494
TEM data including air volume and EDS for NSHS samples.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293781
TEM analysis for New Stuyvesant H.S. exterior & interior; received 10/21/01.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
TEM analysis of air samples at New Stuyvesant H.S., Oct 2001.
Similar indexed content
TEM analysis with structure ID and EDS; exterior/interior building data.
Similar indexed content
NYC-WTC_000188696
Laboratory report presenting transmission electron microscopy results for asbestos fibers collected during an inspection of a high school.
Similar indexed content
NYC-WTC_000188694
Document containing transmission electron microscopy data for asbestos fiber identification in air samples from a high school building.
Similar indexed content
NYC-WTC_000293494
TEM data including air volume and EDS for NSHS samples.
Similar indexed content